Genesis DM Model: 6053000A1
Transmitters And Receivers, Physiological Signal, Radiofrequency. 510(k) K101242, from Honeywell Hommed, LLC (Brookfield, WI). Product code DRG, class 2.
As of Nov 19, 2026, K101242 is an FDA 510(k) held by Honeywell Hommed, LLC, substantially equivalent on Jun 11, 2010 after 39 days, with no recalls tied to it in FDA's recall database.
- Review time: 39 days
- Recalls: 0
- Cited as a predicate by: 5 devices
The Honeywell HomMed Genesis DM Monitor is designed to retrospectively monitor vital signs. Vital signs include noninvasive blood pressure, pulse rate, and weight. Data from optional commercial stand-alone products extend Genesis DM Monitor's measurement capabilities. Data from the Genesis DM Monitor can be transmitted via a communication module to a central viewing station for display.
- Genesis Otc MonitorK061087 · Honeywell Hommed, LLC · Jun 9, 2006
- Omron Automatic Blood Pressure Monitor With Comfit Cuff, Model Hem 780 N3K061822 · Omron Healthcare, Inc. · Aug 2, 2006
- Genesis Touch SystemK141792 · Honeywell Hommed · Nov 25, 2014
- Myhealthpoint Telehealth ManagerK132930 · Entra Health Systems · Apr 14, 2014
- Connected Care Mobile ApplicationK120325 · Watermark Medical · Jul 18, 2012
- Genesis Touch SystemK112858 · Honeywell Hommed, LLC · Jan 24, 2012
- M3810A Philips Telemonitoring System With Edevice Bridged130K103214 · Lifeline Systems, Inc. · Dec 1, 2010
- UbiqVue™ 2AYe Cardiac System (UX2253)K261569 · Lifesignals, Inc. · Jul 9, 2026
- Perin Health System (PHD80060-2)K252984 · Perin Health Devices, LLC · Jan 22, 2026
- EasyTeleMed (2.0.2)K252440 · Ingeniars S.R.L. · Oct 2, 2025
- TeleRehab Aermos Cardiopulmonary RehabilitationK250259 · The ScottCare Corporation · Jun 4, 2025
- iBSMK243837 · Iorbit Digital Technologies Private Limited · May 16, 2025
- UbiqVue™ 2A Multi-parameter System (UX2550)K242018 · Lifesignals, Inc. · Nov 12, 2024
- BioButton SystemK241101 · Biointellisense, Inc. · Sep 26, 2024
- ANNE ChestK240251 · Sibel Health, Inc. · Jun 3, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- May 3, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2910
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files