Pta-Plus Pta Balloon Cather 5 Mm X 4CM, Pta-Plus Pta Balloon Catheter 6MM X 4CM
Catheter, Embolectomy. 510(k) K100842, from Hotspur Technologies (Mountain View, CA). Product code DXE, class 2.
As of Nov 17, 2026, K100842 is an FDA 510(k) held by Hotspur Technologies, substantially equivalent on Jul 12, 2010 after 109 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jul 12, 2010
- Review time: 109 days
- Recalls: 0
- Cited as a predicate by: 1 device
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Fogarty Arterial Embolectomy Ii CatheterK901625 · Baxter Healthcare Corp · Jul 6, 1990
- Vaccess Pta Balloon Dilatation CatheterK073472 · C.R. Bard, Inc. · Jan 9, 2008
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- InThrill Thrombectomy SystemK223613 · Inari Medical, Inc. · Mar 17, 2023
Other DXE Clearances
The newest 510(k)s for the same product code; their median review was 173 days; see every DXE device- Fogarty Thru-Lumen Embolectomy CatheterK240078 · Edwards Lifesciences, LLC · Aug 28, 2024
- Fogarty Fortis Arterial Embolectomy CatheterK241330 · Edwards Lifesciences · Jul 2, 2024
- Fogarty Venous Thrombectomy CathetersK233819 · Edwards Lifesciences, LLC · May 22, 2024
- Fogarty Arterial Embolectomy Catheter with Gate ValveK233820 · Edwards Lifesciences · May 22, 2024
- Fogarty Corkscrew Catheters; Fogarty Graft Thrombectomy CathetersK233619 · Edwards Lifesciences · May 20, 2024
- Merlin Aspiration SystemK213771 · Mivi Neurovascular, Inc. · Jan 27, 2022
- Python Catheter/Over-the-Wire Latis Graft Cleaning CatheterK202049 · Applied Medical Resources Corporation · Sep 7, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 25, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.5150
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files