Qrs Card S-T Segment Analysis Patient Monitoring System Model: Qrs Card Usb
Electrocardiograph. 510(k) K100813, from Pulse Biomedical, Inc. (Norristown, PA). Product code DPS, class 2.
As of Nov 20, 2026, K100813 is an FDA 510(k) held by Pulse Biomedical, Inc., substantially equivalent on Jul 23, 2010 after 122 days, with no recalls tied to it in FDA's recall database.
- Review time: 122 days
- Recalls: 0
This device is intended for use as a patient monitor for any patient undergoing ECG S-T Segment Analysis and/or ECG stress analysis during rest or exercise. Exercise can be performed treadmill or bicycle ergometer use. The intended use locations are either in a physician's office, hospital or rehabilitation facilities, or similar use areas.
- Pulse Biomedical Inc, Qrs Card S-T Segment Analysis Monitoring SystemK972255 · Pulse Biomedical, Inc. · Jul 7, 1998
- PC Ecg 1200W SystemK080141 · Norav Medical , Ltd. · Apr 25, 2008
- Pelex-04 Wireless Electrocardiograph With Software AccessoriesK061977 · Pinmed, Inc. · Jul 21, 2006
- Kinetic Software LibraryK260640 · Monebo Technologies, Inc. · Oct 23, 2026
- MyoVista wavECG (DG-200-B15-003)K260005 · HeartSciences, Inc. · Oct 5, 2026
- QCA 10 Electrocardiograph (QCARD-10); QCA 10W Electrocardiograph (QCARD-10W)K260250 · QT Medical, Inc. · Sep 29, 2026
- SE-1202 Series Electrocardiograph (Model: SE-1202, SE-1202E)K252463 · Edan Instruments, Inc. · Jul 2, 2026
- MAC 7 Resting ECG Analysis SystemK251670 · Ge Medical Systems Information Technologies, Inc. · Jan 26, 2026
- AccurECG Analysis System (v2.0)K252361 · Accurkardia, Inc. · Dec 22, 2025
- Withings BeamO (SCT02)K252474 · Withings · Nov 10, 2025
- Cardiologs Holter PlatformK250569 · Philips France Commercial · Aug 6, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Mar 23, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2340
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files