Modifcation To: NuVasive Neurovision Emg Endotracheal Tube
Stimulator, Electrical, Evoked Response. 510(k) K094054, from Nuvasive, Inc. (San Diego, CA). Product code GWF, class 2.
As of Nov 19, 2026, K094054 is an FDA 510(k) held by Nuvasive, Inc., substantially equivalent on May 14, 2010 after 134 days, with no recalls tied to it in FDA's recall database.
- Review time: 134 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The NeuroVision EMG Endotracheal Tube is intended for use with any compatible monitoring system during surgical procedures for continuous EMG neurological monitoring and status assessment of the nerves supplying the laryngeal musculature as well as for providing an open airway for patient ventilation.
- NuVasive Neuro Vision SystemK090298 · Nuvasive, Inc. · Jun 8, 2009
- Ecom CV4 Endotracheal Cardiac Output MonitorK032491 · Imagyn Medical Technologies, Inc. · Sep 4, 2003
- Contact Emg Rotatable Endotracheal TubeK050162 · Medtronic Xomed, Inc. · Mar 3, 2005
- NuVasive Emg Endotracheal TubeK133530 · Nu Vasive, Incorporated · May 2, 2014
- Next Gen Emg Endotracheal TubeK112686 · Medtronic Xomed, Inc. · Jun 27, 2012
- Neurovision Ink Printed Endotracheal Tube ElectrodeK110989 · Neurovision Medical Products, Inc. · Nov 3, 2011
- ISIS Headboxes, ISIS Neurostimulator, ISIS Xpert Plus, ISIS Xpert, ISIS XpressK263010 · inomed Medizintechnik GmbH · Sep 24, 2026
- BraiN20® (BraiN20)K253301 · Time IS Brain, S.L. · Jun 27, 2026
- SafeOp 3: Neural Informatix SystemK252842 · Alphatec Spine, Inc. · Jan 11, 2026
- Nicolet EDXK243982 · Natus Neurology Incorporated · Jan 22, 2025
- Natus Ultrapro S100 (982A0594)K243495 · Natus Neurology Incorporated · Dec 12, 2024
- Delphi StimulatorK242345 · Quantalx Neuroscience · Nov 5, 2024
- SafeOp 3: Neural Informatix SysteemK234092 · Alphatec Spine, Inc. · Apr 19, 2024
- MEGA-IOM system with Neuro-IOM.NET software (32/B - 32/S - 16/S)K234080 · Soterix Medical, Inc. · Mar 25, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Dec 31, 2009
- Review panel
- Neurology
- Regulation
- 21 CFR 882.1870
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files