Arca
Skip to content
Tools
Tools

Trilogy 202 Ventilator

Ventilator, Continuous, Facility Use. 510(k) K093905, from Respironics, Inc. (Murrysville, PA). Product code CBK, class 2.

As of Nov 19, 2026, K093905 is an FDA 510(k) held by Respironics, Inc., substantially equivalent on May 12, 2010 after 141 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 141 days
  • Recalls: 3
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Indications for Use 510(k) Number (if known): K093905 Device Name: Trilogy 202 Ventilator The Respironics Trilogy 202 system provides continuous or intermittent ventilatory support for the care of individuals who require mechanical ventilation with or without air/oxygen blending. Trilogy 202 is intended for pediatric through adult patients weighing at least 5 kg (11 lbs.).

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K093905, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Jan 18, 2016Z-1065-2016Software IssueTerminated
Feb 11, 2014Z-1143-2014Internal testing revealed a potentially defective component on the power management board that could affect the function of certain Trilogy Ventilators resulting in loss of therapy to patients.Terminated
Apr 27, 2012Z-2024-2012The specified Trilogy units are being recalled because of the potential for a faulty component in the power supply.Terminated

Other CBK clearances

The newest 510(k)s for the same product code; their median review was 235 days; see every CBK device

Record

Type
Abbreviated
Received
Dec 22, 2009
Review panel
Anesthesiology
Regulation
21 CFR 868.5895

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files