Planmeca Promax 3D Max
System, X-Ray, Extraoral Source, Digital. 510(k) K093590, from Planmeca Oy (Helsinki, FI). Product code MUH, class 2.
As of Nov 20, 2026, K093590 is an FDA 510(k) held by Planmeca Oy, substantially equivalent on May 12, 2010 after 174 days, with no recalls tied to it in FDA's recall database.
- Review time: 174 days
- Recalls: 0
- Cited as a predicate by: 4 devices
Planmeca Promax 3D Max, is a three dimensional Cone Beam Volumetric Tomography (CBVT) x-ray system, which is intended to produce three-dimensional images of the human teeth, jaw and skull. The device uses cone shaped x-ray beam projected on to a flat panel detector, and the examined volume image is reconstructed to be viewed in 3D viewing stations.
- Planmeca Promax 3DK060328 · Planmeca Oy · Mar 15, 2006
- eco-x Series (eco-x, eco-x-s)K211159 · Hdx Will Corp. · Dec 30, 2021
- Planmeca ProMax 3D Max, Planmeca MaximityK160506 · Planmeca Oy · May 20, 2016
- DENTRIa seriesK160140 · Hdx Will Corp. · Sep 30, 2016
- Planmeca Promax 3D MidK103689 · Planmeca Oy · Mar 17, 2011
- EzSensor HDK261663 · Qpix Solutions, Inc. · Sep 30, 2026
- SOTA Cloud Smart Sensor (1.5)K251793 · Sota Cloud Corp. · Mar 3, 2026
- EzSensor HD, EzSensor UHDK252570 · Qpix Solutions, Inc. · Nov 10, 2025
- Cocoon Solo (DX-7020s)K250687 · Dexcowin Global, Inc. · Oct 24, 2025
- Digital X-Ray DentiMax Pro Imaging SystemK251206 · Dentimax, Inc. · Sep 24, 2025
- VistaPano S Ceph 2.0 (VistaPano S Ceph); VistaPano S 2.0 (VistaPano S); ProVecta S-Pan Ceph 2.0 (ProVecta S-Pan Ceph);…K240040 · VATECH Co., Ltd. · Oct 25, 2024
- X Sensor (Model: IOS-A15IF, HDI-15DGF)K242778 · Qpix Solutions, Inc. · Oct 11, 2024
- DUO1 and DUO2K241649 · Zinnovi, Inc. · Jul 5, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 19, 2009
- Review panel
- Dental
- Regulation
- 21 CFR 872.1800
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files