Starfill 2B HV (High Viscosity) Rockcore, Model: 90838 and Starfill 2B LV (Low Viscosity), Model: 90150
Material, Tooth Shade, Resin. 510(k) K092912, from Danville Materials, Inc. (San Ramon, CA). Product code EBF, class 2.
As of Nov 22, 2026, K092912 is an FDA 510(k) held by Danville Materials, Inc., substantially equivalent on Dec 16, 2009 after 85 days, with no recalls tied to it in FDA's recall database.
- Review time: 85 days
- Recalls: 0
- Cited as a predicate by: 1 device
“StarFill 2B HV and LV are dual-cure (auto-cure with light-cure acceleration) polymer-based dental restoratives that when applied to dental surfaces pretreated with suitable primers or adhesives are indicated for use as the first increment under posterior composites; for core build-ups; and for luting posts, crowns, veneers and any application where light transmission may be inadequate.”
- Chairside Attachment Processing MaterialK140570 · Zest Anchors, LLC · Jun 16, 2014
- Core·it DualK262982 · Spident Co., Ltd. · Sep 21, 2026
- Cerasmart ForteK262202 · GC America, Inc. · Sep 10, 2026
- Flowable Restorative Material (KP-Flow LF, KP-Flow MF, KP-Flow HF)K261695 · Guilin Kevin Peter Technology Co., Ltd. · Aug 31, 2026
- Tetric plus Fill;Tetric plus FlowK261485 · Ivoclar Vivadent, Inc. · Jul 1, 2026
- Transcend Bulk Fill Flowable CompositeK262228 · Ultradent Products, Inc. · Jul 1, 2026
- SRGC-06K261246 · GC America, Inc. · Jun 18, 2026
- DiafilK261093 · DiaDent Group International · Jun 2, 2026
- DIAFIL Bulk FLOW (Economic Package);DIAFIL Bulk FLOW (Refill Package);DIAFIL Bulk FLOW (0.5g)K261071 · DiaDent Group International · May 19, 2026
- Type
- Traditional
- Received
- Sep 22, 2009
- Review panel
- Dental
- Regulation
- 21 CFR 872.3690
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files