Arca
Skip to content
Tools
Tools

Ventstar Resuscitaire, Model MP00311, Ventstar Resuscitaire Ceu, Model MP00310

Attachment, Breathing, Positive End Expiratory Pressure. 510(k) K092029, from Draeger Medical AG & Co. KG (Telford, PA). Product code BYE, class 2.

As of Nov 19, 2026, K092029 is an FDA 510(k) held by Draeger Medical AG & Co. KG, substantially equivalent on Aug 6, 2010 after 396 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 396 days
  • Recalls: 1

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The VentStar Resuscitaire CEU with PEEP valve is indicated as an accessory to add positive end expiratory pressure breathing capability. The valve is designed into the breathing circuit T-Piece with a standard fitting for face mask, laryngeal mask or endotracheal tube.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K092029, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Sep 3, 2026Z-3252-2026Potential cracks in the hose, which could lead to leakage or the hose falling off.Open

Record

Type
Traditional
Received
Jul 6, 2009
Review panel
Anesthesiology
Regulation
21 CFR 868.5965

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files