Acl Top 700 Las
Instrument, Coagulation, Automated. 510(k) K091980, from Instrumentation Laboratory CO (Bedford, MA). Product code GKP, class 2.
As of Nov 17, 2026, K091980 is an FDA 510(k) held by Instrumentation Laboratory CO, substantially equivalent on Sep 22, 2009 after 83 days, with 24 recalls tied to it in FDA's recall database.
- Substantially equivalent: Sep 22, 2009
- Review time: 83 days
- Recalls: 24
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe ACL TOP is a bench top, fully automated, random access analyzer designed specifically for in vitro diagnostic clinical use in the hemostasis laboratory for coagulation and/or fibrinolysis testing in the assessment of thrombosis and/or hemostasis. The system provides results for both direct hemostasis measurements and calculated parameters.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Acl Top (With System Software V3.0.0)K073377 · Instrumentation Laboratory CO · May 4, 2008
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- Acl Top (Acl Top 700, Acl Top 700 Cts, Acl Top 700 Las, Acl Top 500 Cts, Acl Top 300 Cts)K160276 · Instrumentation Laboratory CO · Mar 3, 2016
- Acl Top Family 50 Series: Acl Top 350 Cts; Acl Top 550 Cts; Acl Top 750; Acl Top 750 Cts;…K150877 · Instrumentation Laboratory CO · Dec 13, 2015
Recalls
Recalls FDA ties to K091980, newest first; each opens FDA's recall record| Jun 3, 2014 | Z-2064-2014Potential for sample misidentification. | Terminated |
| Jun 3, 2014 | Z-2062-2014Potential for sample misidentification. | Terminated |
| Jun 3, 2014 | Z-2060-2014Potential for sample misidentification. | Terminated |
| Jun 3, 2014 | Z-2065-2014Potential for sample misidentification. | Terminated |
| Jun 3, 2014 | Z-2061-2014Potential for sample misidentification. | Terminated |
| Jun 3, 2014 | Z-2063-2014Potential for sample misidentification. | Terminated |
| Jun 3, 2014 | Z-2066-2014Potential for sample misidentification. | Terminated |
| Jul 19, 2013 | Z-2245-2013Potential carryover issue that can can cause shortened APTT clotting times on the instrument. | Terminated |
| Jul 19, 2013 | Z-2244-2013Potential carryover issue that can can cause shortened APTT clotting times on the instrument. | Terminated |
| Jul 19, 2013 | Z-2246-2013Potential carryover issue that can can cause shortened APTT clotting times on the instrument. | Terminated |
| Jul 19, 2013 | Z-2250-2013Potential carryover issue that can can cause shortened APTT clotting times on the instrument. | Terminated |
| Jul 19, 2013 | Z-2247-2013Potential carryover issue that can can cause shortened APTT clotting times on the instrument. | Terminated |
| Jul 19, 2013 | Z-2248-2013Potential carryover issue that can can cause shortened APTT clotting times on the instrument. | Terminated |
| Jul 19, 2013 | Z-2249-2013Potential carryover issue that can can cause shortened APTT clotting times on the instrument. | Terminated |
| Aug 3, 2012 | Z-2388-2012Low Abnormal Fibrinogen Sample Reports as Normal and High Fibrinogen Sample Reports as Low | Terminated |
| Aug 3, 2012 | Z-2387-2012Low Abnormal Fibrinogen Sample Reports as Normal and High Fibrinogen Sample Reports as Low | Terminated |
| Aug 3, 2012 | Z-2390-2012Low Abnormal Fibrinogen Sample Reports as Normal and High Fibrinogen Sample Reports as Low | Terminated |
| Aug 3, 2012 | Z-2392-2012Low Abnormal Fibrinogen Sample Reports as Normal and High Fibrinogen Sample Reports as Low | Terminated |
| Aug 3, 2012 | Z-2389-2012Low Abnormal Fibrinogen Sample Reports as Normal and High Fibrinogen Sample Reports as Low | Terminated |
| Aug 3, 2012 | Z-2391-2012Low Abnormal Fibrinogen Sample Reports as Normal and High Fibrinogen Sample Reports as Low | Terminated |
| Aug 13, 2010 | Z-0135-2011Software: New data check, "Multiple Threshold Check", was added to identify and fail abnormal (bimodal) clot curves | Terminated |
| Aug 13, 2010 | Z-0136-2011Software: New data check, "Multiple Threshold Check", was added to identify and fail abnormal (bimodal) clot curves | Terminated |
| Aug 13, 2010 | Z-0137-2011Software: New data check, "Multiple Threshold Check", was added to identify and fail abnormal (bimodal) clot curves | Terminated |
| Aug 13, 2010 | Z-0138-2011Software: New data check, "Multiple Threshold Check", was added to identify and fail abnormal (bimodal) clot curves | Terminated |
Other GKP Clearances
The newest 510(k)s for the same product code; see every GKP device- ACL TOP Family 50 Series (ACL TOP 750; ACL TOP 750 CTS; ACL TOP 750 LAS; ACL TOP 550 CTS;…K242127 · Instrumentation Laboratory (IL) Co. · Aug 16, 2024
- ACL TOP Family 70 SeriesK231031 · Instrumentation Laboratory Company · Jun 21, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jul 1, 2009
- Review panel
- Hematology
- Regulation
- 21 CFR 864.5400
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files