Ucp Rapid Drug Screening Buprenorphine, Amp 300, Mamp 500, Coc 150 Test
Enzyme Immunoassay, Opiates. 510(k) K091612, from Ucp Biosciences, Inc. (San Jose, CA). Product code DJG, class 2.
As of Nov 29, 2026, K091612 is an FDA 510(k) held by Ucp Biosciences, Inc., substantially equivalent on Feb 24, 2010 after 266 days, with no recalls tied to it in FDA's recall database.
- Review time: 266 days
- Recalls: 0
- Cited as a predicate by: 1 device
The UCP Drug Screening Buprenorphine, Amphetamine 300, Methamphetamine 500, Cocaine 150 Tests are rapid, qualitative, competitive binding immunoassays for the detection the following drug in human urine: Test Calibrator Cut-off Buprenorphine Buprenorphine 10 ng/mL Amphetamine D-Amphetamine 300 ng/mL Methamphetamine D-Methamphetamine 500 ng/mL Cocaine Benzoylcgonine 150 ng/mL The tests contain…
- Ucp Home Drug Screening Test; Cards, CupsK130463 · Ucp Biosciences, Inc. · May 15, 2013
- Labcorp Fentanyl Urine Visual TestK252684 · Medtox Diagnostics, Inc. · Jan 29, 2026
- Evidence MultiSTAT DOA Urine MultiPlexK250741 · Randox Laboratories Limited · Jan 23, 2026
- LZI Buprenorphine II Enzyme ImmunoassayK253082 · Lin-Zhi International, Inc. · Jan 16, 2026
- SEFRIA™ Hydrocodone Oral FluidK252520 · Immunalysis Corporation · Sep 11, 2025
- Healgen® AccuFluor Fentanyl Fluorescence Immunoassay (FIA)Test Kit - Qualitative; Healgen® Immunofluorescence Analyzer…K251972 · Healgen Scientific,, LLC · Aug 15, 2025
- LZI Fentanyl III Enzyme ImmunoassayK251634 · Lin-Zhi International, Inc. · Jun 18, 2025
- BioSieve™ Fentanyl FIA Test Kit; BioSieve™ ToxiSmart FIA ReaderK240124 · Vivachek Biotech (Hangzhou) Co., Ltd. · Jun 14, 2024
- Dochek® Multi-Drug Urine Test Dipcard Rx; Dochek® Multi-Drug Urine Test DipcardK240698 · Guangzhou Decheng Biotechnology Co., Ltd. · May 10, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 3, 2009
- Review panel
- Clinical Toxicology
- Regulation
- 21 CFR 862.3650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files