Single Use 3-Lumen Extraction Balloon V, Model V B-V233P-A,B-V233P-B,B-V433P-A,B-V433P-B, BV243Q-A, B-V243Q-B, B-V443Q-A
Dislodger, Stone, Biliary. 510(k) K091495, from Olympus Medical Systems Corporation (Center Valley, PA). Product code LQR, class 2.
As of Nov 20, 2026, K091495 is an FDA 510(k) held by Olympus Medical Systems Corporation, substantially equivalent on Sep 3, 2009 after 106 days, with 3 recalls tied to it in FDA's recall database.
- Review time: 106 days
- Recalls: 3
These instruments have been designed to be used with Olympus endoscopes to endoscopically remove stones such as calculi, pancreatic and common bile duct stones, to remove bile sludge from the biliary system and to facilitate injection of contrast medium into the biliary system 6 Comparison of
- Single Use 3-Lumen Balloon Catheter, Models B-230Q-A and B-230Q-BK033333 · Aomori Olympus Co., Ltd. · Nov 14, 2003
| Started | Recall | Status |
|---|---|---|
| Jan 4, 2021 | Z-0966-2021, Z-0967-2021, Z-0968-2021Inspection confirmed a small percentage of sterile packages with inadequate package seal (partial heat seal). Patients may develop infections if non-sterile equipment is used. | Terminated |
- Disposable Stone Extraction BasketK253056 · Zhejiang Soudon Medical Technology Co., Ltd. · Apr 3, 2026
- Single Use Retrieval Basket V FG-V421PR/V422PR/V431P/V432PK243807 · Olympus Medical Systems Corp. · Mar 18, 2025
- Extraction BasketK243471 · Micro-Tech (Nanjing) Co., Ltd. · Dec 16, 2024
- Single-use Extraction BasketsK240192 · Scivita Medical Technology Co., Ltd. · Oct 15, 2024
- Stone Extraction BasketsK230598 · Jiangsu Vedkang Medical Science and Technology Co., Ltd. · Sep 12, 2023
- SpyGlass Discover Retrieval BasketK203322 · Boston Scientific Corporation · May 26, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 20, 2009
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5010
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files