Digital Radiography, Model CXDI-55C
Solid State X-Ray Imager (Flat Panel/Digital Imager). 510(k) K091436, from Canon, Inc. (Lake Success, NY). Product code MQB, class 2.
As of Nov 19, 2026, K091436 is an FDA 510(k) held by Canon, Inc., substantially equivalent on May 29, 2009 after 15 days, with 1 recall tied to it in FDA's recall database.
- Review time: 15 days
- Recalls: 1
- Cited as a predicate by: 2 devices
DIGITAL RADIOGRAPHY CXDI-55C provides digital image capture for conventional film/screen radiographic examinations. The device is intended to replace radiographic film/screen systems in all general purpose diagnostic procedures. This device is not intended for mammography applications.
- Digital Radiography CXDI-50CK060433 · Canon, Inc. · Mar 10, 2006
- Nova Fa Dr SystemK133782 · Sedecal., Sa. · Mar 21, 2014
- Digital RadiographyK111682 · Canon Inc. -Medical Equipment Group · Sep 2, 2011
| Started | Recall | Status |
|---|---|---|
| Nov 1, 2010 | Z-2265-2012Screws holding the 55REF circuit board are loosening and roaming inside of the sealed sensor. | Terminated |
- 0909FCE, 0909FCE-HSK253800 · Rayence Co., Ltd. · Jul 31, 2026
- Vivix-S 4386W (FXRD-4386WA)K260820 · Vieworks Co., Ltd. · Jun 18, 2026
- Universal 1417PIK252996 · Konica Minolta Healthcare Americas, Inc. · Jun 12, 2026
- Lux HD 2530 detector (Lux HD 2530)K252911 · Iray Imaging Technology (Haining) Limited · Oct 9, 2025
- Yushan X-Ray Flat Panel DetectorK250211 · Innocare Optoelectronics Corp. · Jul 22, 2025
- Skr 3000K250665 · Konica Minolta, Inc. · Jun 17, 2025
- Wireless/ Wired X-Ray Flat Panel DetectorsK243734 · Allengers Medical Systems Limited · Apr 18, 2025
- Expd 114; Expd 114G; Expd 114P; Expd 114PGK242770 · DRTECH Corporation · Mar 20, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- May 14, 2009
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1680
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files