- Review time: 119 days
- Recalls: 3
- Cited as a predicate by: 3 devices
LUCAS 2 Chest Compression System is to be used for performing external cardiac compressions on adult patients who have acute circulatory arrest defined as absence of spontaneous breathing and pulse, and loss of consciousness. LUCAS 2 must only be used in cases where chest compressions are likely to help the patient.
- Modification To LucasK062401 · Jolife AB · Sep 28, 2006
- Thumper, Model: 1008K073079 · Michigan Instruments, Inc. · Feb 14, 2008
- Autopulse Resuscitation System, Model 100K072527 · Zoll Circulation · Mar 19, 2008
- LUCAS 3 Chest Compression SystemK161768 · Jolife AB · Nov 9, 2016
- ROSC-U Mini Chest Compressor (RMCC)K153628 · Resuscitation International, LLC · Jan 30, 2016
- RMU-1000 Automated Chest Compression SystemK141809 · Defibtech, LLC · Oct 27, 2014
| Apr 13, 2026 | Z-2161-2026Due to a subset of chest compression systems/devices where the service performed on the systems were not appropriately documented (The documents for the service performed to justify the passing results were not include… | Open |
| May 21, 2025 | Z-1998-2025Due to demonstration units of chest compression system being provided to a customer which may potentially be utilized for clinical use. | Open |
| Feb 8, 2011 | Z-1664-2011LUCAS 2 Chest Compression System may have malfunctions resulting from the failure of a hood probe on the device that connects to the battery. The device may stop in fail safe mode and the LEDs will start flickering or… | Terminated |
- AutoPulse NXT Resuscitation SystemK221700 · Zoll Circulation, Inc. · Mar 9, 2023
- RMU-2000 Automated Chest Compression SystemK211289 · Defibtech, LLC · Nov 9, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 18, 2009
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.5200
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files