Confidant, Model 2.6
Transmitters And Receivers, Physiological Signal, Radiofrequency. 510(k) K083331, from Confidant, Inc. (Durham, NC). Product code DRG, class 2.
As of Nov 17, 2026, K083331 is an FDA 510(k) held by Confidant, Inc., substantially equivalent on Jan 9, 2009 after 58 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jan 9, 2009
- Review time: 58 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFConfidant 2.6 is intended for personal use by out-of-hospital patients as a means to retrospectively collect and record physiologic measurements from home monitoring devices (including blood glucose meters, blood pressure cuffs and weight scales). The data is transmitted to a database server where customized messages are generated by the system and returned to the patient.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Confidant 2.5K072698 · Confidant, Inc. · Nov 16, 2007
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- Ascot Home Medical Monitoring System (Hmms)K103643 · Ascot Technologies, Inc. · Oct 6, 2011
- Modification To Medicompass ConnectK091021 · Imetrikus, Inc. · Jul 15, 2009
Other DRG Clearances
The newest 510(k)s for the same product code; their median review was 126 days; see every DRG device- UbiqVue 2AYe Cardiac System (UX2253)K261569 · Lifesignals, Inc. · Jul 9, 2026
- Perin Health System (PHD80060-2)K252984 · Perin Health Devices, LLC · Jan 22, 2026
- EasyTeleMed (2.0.2)K252440 · Ingeniars S.R.L. · Oct 2, 2025
- TeleRehab Aermos Cardiopulmonary RehabilitationK250259 · The ScottCare Corporation · Jun 4, 2025
- iBSMK243837 · Iorbit Digital Technologies Private Limited · May 16, 2025
- UbiqVue 2A Multi-parameter System (UX2550)K242018 · Lifesignals, Inc. · Nov 12, 2024
- BioButton SystemK241101 · Biointellisense, Inc. · Sep 26, 2024
- ANNE ChestK240251 · Sibel Health, Inc. · Jun 3, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Nov 12, 2008
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2910
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files