INFX-8000H, Infinix-I
System, X-Ray, Fluoroscopic, Image-Intensified. 510(k) K082830, from Toshiba America Medical Systems, In.C (Tustin, CA). Product code JAA, class 2.
As of Nov 18, 2026, K082830 is an FDA 510(k) held by Toshiba America Medical Systems, In.C, substantially equivalent on Oct 10, 2008 after 14 days, with 2 recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 10, 2008
- Review time: 14 days
- Recalls: 2
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThis device is a digital radiography/fluoroscopy system used in a diagnostic angiography configuration. This system is indicated for use in diagnostic and angiographic procedures for blood vessels in the heart, brain, abdomen and lower extremities.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- INFX-8000C (Infinix Cc-I And Vc-I)K081621 · Toshiba America Medical Systems, In.C · Jun 23, 2008
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Alphenix, INFX-8000H/B, V8.0K182546 · Canon Medical Systems Corporation · Oct 17, 2018
Recalls
Recalls FDA ties to K082830, newest first; each opens FDA's recall record| Dec 29, 2017 | Z-0845-2018During an examination a device error occurred and the ceiling drive operation was disabled. It was found that the fastening bolts of the driving portion of the ceiling drive loosened cause the error. | Terminated |
| Oct 3, 2011 | Z-0331-2012The recall was initiated because Toshiba has confirmed that during patient transfer from a gurney to the catherization table, the tabletop may rotate unexpectedly when sufficient force is applied to the tabletop. The… | Terminated |
Other JAA Clearances
The newest 510(k)s for the same product code; their median review was 110 days; see every JAA device- Nexus DRF Digital X-ray Imaging SystemK253103 · Varex Imaging Corporation · May 29, 2026
- Insight Enhanced™ DRF (EN-1002-01)K251650 · Imaging Engineering, LLC · Sep 16, 2025
- Soteria E-ViewK242488 · Omega Medical Imaging, LLC · Jan 6, 2025
- Adora DRFi (04550010)K242948 · Nrt X-Ray A/S · Dec 23, 2024
- TRIDENT Mobile Fluoroscopy SystemK233380 · Dornier Medtech America · Jun 26, 2024
- ProxiDiagnost N90 / Precision CRF (706110, 706400)K233945 · Philips Medical Systems Dmc GmbH · Jan 11, 2024
- CombiDiagnost R90K232910 · Philips Medical Systems Dmc GmbH · Oct 19, 2023
- XIDF-AWS801, Angio Workstation (Alphenix Workstation), V9.5K232526 · Canon Medical Systems Corporation · Sep 12, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Sep 26, 2008
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files