Dimension Exl N-Ternmial Pro-Brain Natriuretic Peptide (Ntp) Flex Reagent Cartridge, Model RF623
Test, Natriuretic Peptide. 510(k) K082645, from Siemens Healthcare Diagnostics (Newark, DE). Product code NBC, class 2.
As of Nov 21, 2026, K082645 is an FDA 510(k) held by Siemens Healthcare Diagnostics, substantially equivalent on Sep 22, 2008 after 11 days, with 1 recall tied to it in FDA's recall database.
- Review time: 11 days
- Recalls: 1
The NTP method is an in vitro diagnostic assay for the quantitative measurement of N-terminal pro-brain natriuretic peptide (NT-proBNP) in human serum and plasma on the Dimension® EXL™ integrated chemistry system with LOCI® Module. In individuals suspected of having congestive heart failure (CHF), measurements of NT-proBNP are used as an aid in the diagnosis and assessment of severity.
- Dimension Vista N-Terminal Pro-Brain Natriuretic Peptide (Pbnp) Flex Reagent Cartridge (K6423A), Dimension VistaK080578 · Siemens Healthcare Diagnostics, Inc. · May 16, 2008
| Started | Recall | Status |
|---|---|---|
| Apr 12, 2010 | Z-0461-2011Some LOCI cartridges have sub-optimal seal of the lidstock that can cause rupture of the package at high elevations, causing the cartridge to leak. Use of leaking cartridges may result in inaccurate test results. | Terminated |
- Access BNP IIK262597 · Beckman Coulter, Inc. · Oct 20, 2026
- Access NT-proBNPK262109 · Beckman Coulter, Inc. · Sep 21, 2026
- Access BNP IIK252169 · Beckman Coulter, Inc. · Mar 24, 2026
- Alere NT-proBNP for Alinity iK253539 · Axis-Shield Diagnostics, Ltd. · Feb 18, 2026
- Alere NT-proBNP for Alinity i Reagent KitK241176 · Axis-Shield Diagnostics, Ltd. · Jan 16, 2025
- Access NT-proBNPK232164 · Beckman Coulter, Inc. · Apr 12, 2024
- ADVIA Centaur® NT-proBNPII (PBNPII)K220265 · Siemens Healthcare Diagnostics, Inc. · Sep 24, 2023
- Elecsys proBNP II, Elecsys proBNP II STATK223637 · Roche Diagnostics · Jul 21, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Sep 11, 2008
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1117
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files