Digital Radiography, Flexdr C30
Solid State X-Ray Imager (Flat Panel/Digital Imager). 510(k) K082347, from Konica Minolta Technoproduct Co., Ltd. (New York, NY). Product code MQB, class 2.
As of Nov 19, 2026, K082347 is an FDA 510(k) held by Konica Minolta Technoproduct Co., Ltd., substantially equivalent on Nov 18, 2008 after 95 days, with no recalls tied to it in FDA's recall database.
- Review time: 95 days
- Recalls: 0
- Cited as a predicate by: 1 device
The device is intended for use for medical purpose in a hospital, etc., in order to convert X-ray image data to digital signal and to transfer the converted data to printer, filing system, image display device, etc. 11.
- Direct Digitizer Regius Model 370K051418 · Konica Minolta Medical & Graphic, Inc. · Jul 1, 2005
- Canon Inc., Digital Radiography, Model CXDI-40CK031633 · Canon USA, Inc. · Jun 11, 2003
- Aerodr SystemK102349 · Konica Minolta Medical & Graphic, Inc. · Nov 24, 2010
- 0909FCE, 0909FCE-HSK253800 · Rayence Co., Ltd. · Jul 31, 2026
- Vivix-S 4386W (FXRD-4386WA)K260820 · Vieworks Co., Ltd. · Jun 18, 2026
- Universal 1417PIK252996 · Konica Minolta Healthcare Americas, Inc. · Jun 12, 2026
- Lux HD 2530 detector (Lux HD 2530)K252911 · Iray Imaging Technology (Haining) Limited · Oct 9, 2025
- Yushan X-Ray Flat Panel DetectorK250211 · Innocare Optoelectronics Corp. · Jul 22, 2025
- Skr 3000K250665 · Konica Minolta, Inc. · Jun 17, 2025
- Wireless/ Wired X-Ray Flat Panel DetectorsK243734 · Allengers Medical Systems Limited · Apr 18, 2025
- Expd 114; Expd 114G; Expd 114P; Expd 114PGK242770 · DRTECH Corporation · Mar 20, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 15, 2008
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1680
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files