Regen Collagen Scaffold (Cs)
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen. 510(k) K082079, from Regen Biologics, Inc. (Hackensack, NJ). Product code OLC, class 2.
As of Nov 19, 2026, K082079 is an FDA 510(k) held by Regen Biologics, Inc., substantially equivalent on Dec 18, 2008 after 148 days, with no recalls tied to it in FDA's recall database.
- Review time: 148 days
- Recalls: 0
The ReGen Collagen Scaffold (CS) is intended for use in surgical procedures for the reinforcement and repair of soft tissue injuries of the medial meniscus. In repairing and reinforcing medial meniscal defects, the patient must have an intact meniscal rim and anterior and posterior horns for attachment of the mesh.
- DePuy Restore Orthobiologic Soft Tissue ImplantK031969 · DePuy Orthopaedics, Inc. · Jul 28, 2003
- DePuy Restore Orthobiologic Soft Tissue ImplantK001738 · DePuy Orthopaedics, Inc. · Dec 27, 2000
- DePuy Orthotech Restore Orthobiologic Soft Tissue ImplantK982330 · Depuy, Inc. · Sep 25, 1998
- Sis Fistula PlugK050337 · Cook Biotech, Inc. · Mar 9, 2005
- OrthomendK031188 · Tei Biosciences, Inc. · Jun 27, 2003
- OrthomendK051766 · Tei Biosciences, Inc. · Aug 11, 2005
- Sis Hernia Repair DeviceK974540 · Sentron Medical, Inc. · May 20, 1998
- SurgisisK980431 · Cook Biotech, Inc. · May 28, 1998
- Surgisis SlingK992159 · Cook Biotech, Inc. · Sep 23, 1999
- Sis Plastic Surgery MatrixK034039 · Cook Biotech, Inc. · Feb 18, 2004
- Bioblanket Surgical MeshK043259 · Kensey Nash Corp. · Aug 15, 2005
- BioblanketK041923 · Kensey Nash Corp. · Sep 8, 2004
- RejuvaKnee™ Collagen Meniscus ImplantK242302 · Collagen Matrix, Inc. · Oct 2, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 23, 2008
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.3300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files