Gore Tri-Lobe Balloon Catheter
Catheter, Percutaneous. 510(k) K081799, from W. L. Gore & Associates, Inc. (Flagstaff, AZ). Product code DQY, class 2.
As of Nov 19, 2026, K081799 is an FDA 510(k) held by W. L. Gore & Associates, Inc., substantially equivalent on Oct 3, 2008 after 100 days, with no recalls tied to it in FDA's recall database.
- Review time: 100 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The GORE Tri-Lobc Balloon Catheter is intended to assist in the dilatation of self expanding endoprostheses in large diameter vessels.
- Gore Tri-Lobe Balloon CatheterK033670 · W. L. Gore & Associates, Inc. · May 5, 2004
- Reliant Stent Graft Balloon CatheterK050038 · Medtronic Endovascular Innovations · Apr 13, 2005
- Cook Coda Balloon CatheterK032869 · Cook, Inc. · Nov 19, 2003
- Equalizer Balloon CatheterK021721 · Boston Scientific Corp · Jun 20, 2002
- GORE® Tri-Lobe Balloon CatheterK250410 · W. L. Gore & Associates, Inc. · Jun 2, 2025
- SAT CenterFlow Molding Balloon Catheter (IN20-00313)K243184 · Strait Access Technologies Holdings · Jun 25, 2025
- CrossFAST Integrated Microcatheter Advanced Delivery SystemK262817 · Vantis Vascular, Inc. · Sep 18, 2026
- NHanceITK260559 · IMDS Operation B.V. · Aug 14, 2026
- APRO 35 Swift CatheterK262392 · Alembic, LLC · Aug 12, 2026
- CPS Locator 3D Plus Delivery CatheterK261766 · CenterPoint Systems, LLC · Jul 29, 2026
- SSPC NXT Delivery CatheterK262240 · CenterPoint Systems, LLC · Jul 29, 2026
- Amplatzer TorqVue LP Delivery System; Amplatzer TorqVue LP CatheterK261825 · Abbott · Jul 2, 2026
- Amplatzer TorqVue Exchange SystemK261631 · Abbott Medical · Jun 17, 2026
- Perfect-O Ostial Positioning CatheterK260289 · Balosmark, Inc. · Jun 5, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 25, 2008
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1250
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files