Genesis
Electrosurgical, Cutting & Coagulation & Accessories. 510(k) K081559, from Medisiss (Redmond, OR). Product code GEI, class 2.
As of Nov 19, 2026, K081559 is an FDA 510(k) held by Medisiss, substantially equivalent on Aug 28, 2008 after 86 days, with no recalls tied to it in FDA's recall database.
- Review time: 86 days
- Recalls: 0
The Genesis is indicated for use in surgical procedures (general neurosurgical, laparoscopic, orthopedic, gynecologic, etc.) where monopolar electrosurgical cutting and coagulation are normally used. The Genesis instruments are an alternative to conventional monopolar electrosurgical electrodes used for these indications.
- Valleylab Coated ElectrodesK962044 · Valleylab, Inc. · Aug 30, 1996
- ConMed Stealth Non-Stick Accessory Electrode, Model 138XXXK991855 · Conmedcorp · Jun 15, 1999
- E-Z Clean ElectrodeK913473 · Megadyne Medical Products, Inc. · Sep 6, 1991
- Surginetics AdvantagebladeK062350 · Surginetics · Feb 26, 2007
- SP Electrocautery Device (SP18 Max);SP Electrocautery Device (SP20 Max)K262720 · Single Pass, Inc. · Oct 26, 2026
- SafeAir Electrosurgical Generator with Smoke Evacuation (0795-001-000);SafeAir Generator 3-Pedal Footswitch…K262386 · Stryker Instruments · Oct 20, 2026
- HARMONIC 1100 Shears (HAR1120); HARMONIC 1100 Shears (HAR1136)K254196 · Ethicon Endo-Surgery, LLC · Sep 17, 2026
- Neptune® SafeAir® 10ft Smoke Evacuation Pencil, Square Coated, 70mm Blade, Push Button Switch (0703-046-100);Neptune®…K261959 · Stryker Instruments · Sep 17, 2026
- LigaSure™ RAS Maryland Jaw Vessel Sealer/Divider, Nano-coatedK261070 · Covidien, LLC · Sep 15, 2026
- Potenza PrimeK254185 · Jeisys Medical Incorporated · Sep 11, 2026
- Ellian Enigma RF DeviceK262364 · Ellian Corp · Sep 2, 2026
- Scarlet Pro (Scarlet Pro)K253859 · VIOL Co., Ltd. · Aug 27, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 3, 2008
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4400
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files