Iec Medsight And Medbright
Endoscopic Video Imaging System/Component, Gastroenterology-Urology. 510(k) K080809, from Innovative Endoscopy Components, LLC (Ft. Lauderdale, FL). Product code FET, class 2.
As of Nov 17, 2026, K080809 is an FDA 510(k) held by Innovative Endoscopy Components, LLC, substantially equivalent on Aug 11, 2008 after 143 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Aug 11, 2008
- Review time: 143 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Innovative Endoscopy Components (IEC) MedSIGHT and MedBRIGHT is a video system for endoscopes. MedSIGHT is a color, television camera system (supplies image) and MedBRIGHT is a xenon/halogen light source system (supplies light).
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Karl Storz Endovision Xl Endoscopic Camera SystemK974391 · Karl Storz Imaging, Inc. · Jan 30, 1998
- Endocam Camera Systems 5502 With Electronic Ccd EndoscopeK983279 · Richard Wolf Medical Instruments Corp. · Dec 2, 1998
- 1-CCD Endocam 5520 SystemK023659 · Richard Wolf Medical Instruments Corp. · Jan 29, 2003
- Ksi'S New Camera Architecture (Nca) Video Imaging SystemK003325 · Karl Storz Imaging, Inc. · Apr 27, 2001
- 3-CHIP Video CameraK983566 · Stryker Endoscopy · Jan 11, 1999
- Karl Storz Autoclavable Camera HeadK994090 · Karl Storz Imaging, Inc. · Feb 4, 2000
- 560 High Definition Camera SystemK070266 · Smith & Nephew, Inc. · Feb 22, 2007
- Karl Storz Xenon 300 Light Source For Non-Flash ApplicationsK962595 · KARL STORZ Endoscopy-America, Inc. · Sep 4, 1996
Other FET Clearances
The newest 510(k)s for the same product code; their median review was 158 days; see every FET device- 4K Camera Head OLYMPUS CH-S700-08-LBK262079 · Olympus Medical Systems Corp. · Sep 10, 2026
- FUJIFILM Processor EP-8000;Balloon Controller PB-30;Endoscopy Support Program EW10-VM01K261880 · Fujifilm Corporation · Jul 2, 2026
- HD Camera Head OLYMPUS CH-S200-08-LBK261260 · Olympus Medical Systems Corporation · Jun 24, 2026
- ProVee Video Processing Unit (PV-003)K251734 · Proverum Limited · Sep 24, 2025
- UL UHD-Clear View 4K Camera System (UL-3Chip 4K)K250462 · Univlabs Technologies Private Limited · Aug 11, 2025
- Endoscopic Camera SystemK250204 · Shenzhen Sophway Technology Co., Ltd. · Jul 1, 2025
- FUJIFILM Processor EP-8000; FUJIFILM Endoscope Model EG-860RK243260 · Fujifilm Corporation · Apr 11, 2025
- Visera Elite Iii Video System Center Olympus OTV-S700; Visera Elite Iii Led Light Source Olympus CLL-S700; 4K Camera…K242067 · Olympus Corporations of the Americas · Apr 2, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 21, 2008
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.1500
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files