CP100 & 200 12-LEAD Resting Electrocardiographs
Electrocardiograph. 510(k) K072449, from Welch Allyn, Inc. (Skaneateles Falls, NY). Product code DPS, class 2.
As of Nov 17, 2026, K072449 is an FDA 510(k) held by Welch Allyn, Inc., substantially equivalent on Nov 29, 2007 after 90 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Nov 29, 2007
- Review time: 90 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe electrocardiograph is one of the tools that clinicians use to evaluate, diagnose, and monitor patient cardiac function. The 12-lead ECG interpretive algorithm provides a computer-generated analysis of potential patient cardiac abnormalities, which must be confirmed by a physician with other relevant clinical information.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Welch Allyn Instrument Interface ModuleK001265 · Welch Allyn, Inc. · Jul 13, 2000
- Philips Page Writer Trim Series Cardiograph Including I, Ii, Iii, Models 860286, 860287, 860288, 860289, 860290, 860291K031422 · Philips Medical Systems · Jul 3, 2003
- Caird Technology SpirometerK971336 · Caird Technology · Dec 1, 1998
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- CP150 ElectrocardiographK131573 · Welch Allyn, Inc. · Jul 3, 2013
- Cardio XpK102767 · Bionet Co., Ltd. · Jun 3, 2011
Other DPS Clearances
The newest 510(k)s for the same product code; their median review was 241 days; see every DPS device- Kinetic Software LibraryK260640 · Monebo Technologies, Inc. · Oct 23, 2026
- MyoVista wavECG (DG-200-B15-003)K260005 · HeartSciences, Inc. · Oct 5, 2026
- QCA 10 Electrocardiograph (QCARD-10); QCA 10W Electrocardiograph (QCARD-10W)K260250 · QT Medical, Inc. · Sep 29, 2026
- SE-1202 Series Electrocardiograph (Model: SE-1202, SE-1202E)K252463 · Edan Instruments, Inc. · Jul 2, 2026
- MAC 7 Resting ECG Analysis SystemK251670 · Ge Medical Systems Information Technologies, Inc. · Jan 26, 2026
- AccurECG Analysis System (v2.0)K252361 · Accurkardia, Inc. · Dec 22, 2025
- Withings BeamO (SCT02)K252474 · Withings · Nov 10, 2025
- Cardiologs Holter PlatformK250569 · Philips France Commercial · Aug 6, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated
- Received
- Aug 31, 2007
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2340
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files