Compass
Accelerator, Linear, Medical. 510(k) K072374, from Scanditronix Wellhofer GmbH (Schwarzenbruck, DE). Product code IYE, class 2.
As of Nov 19, 2026, K072374 is an FDA 510(k) held by Scanditronix Wellhofer GmbH, substantially equivalent on Dec 7, 2007 after 106 days, with 3 recalls tied to it in FDA's recall database.
- Review time: 106 days
- Recalls: 3
- Cited as a predicate by: 4 devices
COMPASS is used for quality assurance and plan verification in external beam radiation therapy for multileaf collimated fields and intensity modulated fields. It computes dose (energy per volume deposited by ionizing radiation) three-dimensionally in a geometrical representation of a patient or a phantom.
- Ptw David Imrt QC Verification SystemK062817 · Ptw-New York Corp. · Nov 22, 2006
- Omnipro I'MrtK031634 · Wellhofer Dosimetrie · Aug 29, 2003
- Mucheck - Monitor Unit Validation Program, Model V4.1K012227 · Oncology Data Systems, Inc. · Oct 1, 2001
- ScandiDos Delta4 Discover, Alternative Trade Name: ScandiDos Delta4 Discover+K151426 · Scandidos AB · Jan 29, 2016
- PerfractionK141800 · Sun Nuclear Corporation · Sep 26, 2014
- Mobius3DK140660 · Mobius Medical Systems, LP · Jun 24, 2014
- 3DVHK131862 · Sun Nuclear Corporation · Aug 21, 2013
| Feb 2, 2015 | Z-1212-2015Error in the software. During internal tests of the current development version of the Compass SW it was found that dose reconstruction for DMLC plans when the jaws move or mlc leaves reverse during beam on will not be… | Terminated |
| Sep 25, 2014 | Z-0168-2015Error in the software. A deviation between reconstructed and planned dose distribution may not be detected prior to treatment and this can result in an over or under-estimation of the pretreatment delivered dose. | Terminated |
| Aug 20, 2013 | Z-0456-2014The development partner of IBA informed that there is problem in a SW component used in COMPASS when converting Region of Interest (ROI) geometries to dose grid representation. Under certain conditions this problem… | Terminated |
- AerFrame™ Alignment Laser Box (LBV2)K261865 · Stabilix, LLC · Sep 16, 2026
- EZFluence (RADEZ V2)K261718 · Radformation, Inc. · Aug 31, 2026
- MRIA Radiation Therapy Information System (MRIA)K260733 · Manteia Technologies Co., Ltd. · Aug 26, 2026
- Halcyon, Ethos Radiotherapy System (5.0)K261856 · Varian Medical Systems, Inc. · Aug 3, 2026
- ThinkQA 3K252937 · Dosisoft SA · Jun 12, 2026
- Luna 3DK253004 · Lap GmbH Laser Applikationen · Jun 4, 2026
- AerFrame Patient Immobilization System (AFPIS)K260792 · Stabilix, LLC · May 8, 2026
- Veriqa RT Epid 3DK252258 · Ptw-Freiburg Physikalisch-Technische-Werkstaetten Dr. Pychla · Apr 15, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 23, 2007
- Review panel
- Radiology
- Regulation
- 21 CFR 892.5050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files