Dca Vantage, Model 5075

Assay, Glycosylated Hemoglobin. 510(k) K071466, from Siemens Medical Solutions Diagnostics (Norowood, MA). Product code LCP, class 2.

As of Nov 19, 2026, K071466 is an FDA 510(k) held by Siemens Medical Solutions Diagnostics, substantially equivalent on Oct 9, 2007 after 133 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 133 days
  • Recalls: 1
  • Cited as a predicate by: 5 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The DCA Vantage™ is a semi-automated, benchtop system. It is designed to quantitatively measure the percent Hemoglobin A1c in blood and low concentrations of albumin in urine (microalbuminuria), creatinine in urine, and the albumin/creatinine ratio in urine. The measurement of hemoglobin A1c concentration is recommended for monitoring the long-term glycemic control of persons with diabetes.

Cited as a predicate

5 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K071466, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Jun 30, 2020Z-2747-2020If DCA Vantage Analyzer is configured to run Code 39 with check digit, the scanner is not confirming the integrity of read barcode data using the check digit. Also, if DCA Vantage Analyzer is configured to run Code 39…Terminated

Other LCP clearances

The newest 510(k)s for the same product code; see every LCP device

Record

Type
Special
Received
May 29, 2007
Review panel
Hematology
Regulation
21 CFR 864.7470

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files