Site-Rite 6 Ultrasound System, Model Site-Rite 6
System, Imaging, Pulsed Echo, Ultrasonic. 510(k) K071204, from C.R. Bard, Inc. (Salt Lake City, UT). Product code IYO, class 2.
As of Nov 19, 2026, K071204 is an FDA 510(k) held by C.R. Bard, Inc., substantially equivalent on May 18, 2007 after 17 days, with no recalls tied to it in FDA's recall database.
- Review time: 17 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The Site~Rite ® 6 Ultrasound System with associated probe and accessories provide ultrasound guidance for placement of needles and catheters in vascular structures. Ultrasound guidance may occur intraoperatively or percutaneously. Ultrasound imaging of vascular structures, various organs and structures of the body may also be performed.
- Site-Rite 5 Ultrasound SystemK052517 · C.R. Bard, Inc. · Sep 29, 2005
- Site-Rite 6 Ultrasound System with Pinpoint GT TechnologyK142443 · C.R. Bard, Inc. · Oct 30, 2014
- Site-Rite Vision Ultrasound SystemK100402 · Bard Access Systems, Inc. · Mar 5, 2010
- Ultrasound General Purpose Guidance SystemK093713 · Civco Medical Instruments · Jan 19, 2010
- Evident Vascular™ Guidance SystemK261648 · Evident Vascular, Inc. · Oct 28, 2026
- Accuro XVK262093 · Rivanna Medical, Inc. · Oct 20, 2026
- Lilium one (USM330)K260605 · Lilium Otsuka Co., Ltd. · Oct 16, 2026
- MD-6000S Bladder ScannerK260313 · MEDA Co., Ltd. · Sep 24, 2026
- Accuro 3SK253452 · Rivanna Medical, Inc. · Jul 24, 2026
- ArthurK260190 · ROPCA ApS · Jun 18, 2026
- EdgeFlow UW20K252237 · Edgecare, Inc. · Apr 17, 2026
- Accuro XVK254021 · Rivanna Medical, Inc. · Apr 9, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- May 1, 2007
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1560
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files