Medilogar4, Medilogar12
Recorder, Magnetic Tape, Medical. 510(k) K070818, from Tom Medical Entwicklungs GmbH (Graz, AT). Product code DSH, class 2.
As of Nov 19, 2026, K070818 is an FDA 510(k) held by Tom Medical Entwicklungs GmbH, substantially equivalent on Apr 6, 2007 after 11 days, with no recalls tied to it in FDA's recall database.
- Review time: 11 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The MedilogAR4 and MedilogAR12 Digital Holter Recorders are used to record a 3 channel ECG and 10 measure the time intervals between consecutive N peaks in the ECG. The system is designed for a measuring duration of more than 24h and is therefore worn by the patient throughout the whole day. The preparation for the recording (attaching electrodes, etc.) is undertaken by the technician or doctor.
- Medilog FD4K970902 · Oxford Instruments Medical Systems · May 5, 1997
- DXP1000 Holter RecorderK993618 · Braemar Corp. · Nov 24, 1999
- medilogFDK253562 · Schiller AG · Aug 14, 2026
- Vasomedical Biox CB-1305-C, 3 Channel Ecg Holter Monitor, Model CB-1305-CK083820 · Vasomedical, Inc. · Apr 1, 2009
- LifeLens Physiological MonitorK260157 · LifeLens Technologies, Inc. · Jul 9, 2026
- Rhythm Master ECG Patch (HM-15BB-AX, HM-15BW-AX, HM-15BW-DX)K252389 · Smwmed, Inc. · Apr 23, 2026
- VitaloJAK Clinic (Model 7100)K253293 · Vitalograph , Ltd. · Dec 3, 2025
- Zio® monitor (DFG0001)K243650 · iRhythm Technologies, Inc. · Aug 15, 2025
- AeviceMDK243603 · Aevice Health Pte. , Ltd. · May 5, 2025
- AT-Patch (ATP-C130/ATP-C70)K242583 · Atsens Co., Ltd. · May 2, 2025
- HiCardi+ H100K232670 · MEZOO Co., Ltd. · Sep 20, 2024
- ABPMproK231104 · Somnomedics GmbH · Nov 27, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Mar 26, 2007
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2800
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files