Arca
Skip to content
Tools
Tools

Bioshield-Ercp Biopsy Valve, Model 00711138

Endoscopic Retrograde Cholangiopancreatography (Ercp) Cannula. 510(k) K070420, from United States Endoscopy Group, Inc. (Mentor, OH). Product code ODD, class 2.

As of Nov 19, 2026, K070420 is an FDA 510(k) held by United States Endoscopy Group, Inc., substantially equivalent on Mar 19, 2007 after 27 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 27 days
  • Recalls: 1
  • Cited as a predicate by: 4 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The single use BioShield® - ERCP biopsy valve is used to cover the opening to the biopsy/suction channel of Olympus and G5 and newer Fujinon gastrointestinal endoscopes. It provides access for endoscopic device passage and exchange, helps maintain sufflation, minimizes leakage of biomaterial from the biopsy port throughout the endoscopic procedure, and provides access for irrigation.

Cited as a predicate

4 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K070420, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Oct 31, 2014Z-0861-2015Packaging non-conformance related to the integrity of the sterile pouch seal.Terminated

Other ODD clearances

The newest 510(k)s for the same product code; see every ODD device

Record

Type
Traditional, third-party review
Received
Feb 20, 2007
Review panel
Gastroenterology, Urology
Regulation
21 CFR 876.1500

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files