Syngo Circulation Software Package With Extended Functionality
System, X-Ray, Tomography, Computed. 510(k) K063762, from Siemens AG Medical Solutions (Forchheim, DE). Product code JAK, class 2.
As of Nov 19, 2026, K063762 is an FDA 510(k) held by Siemens AG Medical Solutions, substantially equivalent on Jan 5, 2007 after 16 days, with no recalls tied to it in FDA's recall database.
- Review time: 16 days
- Recalls: 0
- Cited as a predicate by: 5 devices
syngo Circulation is a self-contained image analysis software package for evaluating cardiac and pulmonary CTA, PET and SPECT volume data sets. syngo Circulation combines commercially available digital image processing and visualization tools (MIP thin/thick, MPR thin/thick, vessel aligned MPR, CPR, VRT, AngioView, hybrid visualization), evaluation tools (myocardial and volumetric analysis of the…
- Syngo CirculationK052029 · Siemens AG Medical Solutions · Aug 9, 2005
- Syngo Multimodality WorkstationK010938 · Siemens Medical Solutions USA, Inc. · Jun 26, 2001
- Syngo.Ct Cardiac FunctionK110366 · Siemens AG · Apr 12, 2011
- Corridor4DM V2010 Model: V2010K101279 · Invia · Aug 4, 2010
- Syngo.Ct Coronary AnalysisK100637 · Siemens AG Medical Solutions · May 26, 2010
- Syngo TruedK091373 · Siemens Medical Solutions USA, Inc. · May 20, 2009
- Syngocirculation Dynamicpet, Version 1.0K083327 · Siemens Medical Solutions USA, Inc. · May 18, 2009
- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Dec 20, 2006
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files