Harmonic Focus Curved Shears And Torque Wrench, Harmonic Blue Hand Piece And Test Tip
Instrument, Ultrasonic Surgical. 510(k) K063192, from Ethicon Endo-Surgery, LLC (Cincinnati, OH). Product code LFL, class U.
As of Nov 18, 2026, K063192 is an FDA 510(k) held by Ethicon Endo-Surgery, LLC, substantially equivalent on Jan 30, 2007 after 102 days, with 1 recall tied to it in FDA's recall database.
- Substantially equivalent: Jan 30, 2007
- Review time: 102 days
- Recalls: 1
- Cited as a predicate by: 5 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe HARMONIC FOCUS™ Shears are indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The instruments can be used as an adjunct to or substitute for electrosurgery, lasers, and steel scalpels in general, plastic, pediatric, gynecologic, urologic, exposure to orthopedic structures (such as spine and joint space) and other open procedures.
Cited as a Predicate
5 later 510(k) summaries name this device as a predicate- Harmonic Hand Piece, Blue, Harmonic Hand Piece, GrayK211273 · Ethicon Endo-Surgery, LLC · May 21, 2021
- Medisiss Reprocessed Ultrasonic InstrumentsK124033 · Surgical Instruments Service and Savings, Inc. · Jan 7, 2014
- Reprocessed Harmonic ScalpelK111794 · Sterilmed, Inc. · Jan 11, 2012
- Harmonic Focus ShearsK100597 · Ethicon Endo-Surgery, LLC · Apr 7, 2010
- Reprocessed Ultrasonic Curved Shears With Torque Wrench And Grip Assist Model FCS9, Twblue, GablueK100537 · Ascent Healthcare Solutions · May 12, 2010
Recalls
Recalls FDA ties to K063192, newest first; each opens FDA's recall record| Started | Reason | Status |
|---|---|---|
| Mar 16, 2012 | Z-1673-2012Ethicon Endo-Surgery initiated a voluntary recall due to some lot numbers of the HARMONIC Hand Piece (HP054) and the HARMONIC Blue Hand Piece (HPBLUE), which impacts their compatibility with the HARMONIC Generator 300… | Terminated |
Other LFL Clearances
The newest 510(k)s for the same product code; their median review was 158 days; see every LFL device- TORUS Ultrasonic Aspirator System; and accessories (TORUS Single-Use Tubing Sets, TORUS Single-Use Torque Wrenches,…K261361 · Carl Zeiss Meditec, AG · Oct 15, 2026
- Sonopet iQ Series III Console (5700-050-000); Sonopet iQ+ Straight Handpiece (5500-260-000); Sonopet iQ+ 10mm iQ+ Blade…K262244 · Stryker Instruments · Oct 8, 2026
- neXus Ultrasonic Surgical Aspirator SystemK261448 · Misonix, LLC · Jul 30, 2026
- CUSA® Clarity Ultrasonic Surgical Aspirator SystemK251162 · Integra LifeSciences Corporation · Oct 8, 2025
- SanAgile Ultrasonic Surgery Advanced Portable Controller (SA10); SanAgile Ultrasonic Surgery Advanced Dissector…K242894 · Shanghai Saints Sages Surgical Co., Ltd. · Jun 18, 2025
- Sonopet iQ Ultrasonic Aspirator System (5500-050-000)K243930 · Stryker Instruments · Mar 24, 2025
- Tenex 2nd Generation SystemK241700 · Trice Medical, Inc. · Nov 18, 2024
- CUSA® Clarity Ultrasonic Surgical Aspirator SystemK240493 · Integra LifeSciences Corporation · Jul 11, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Oct 20, 2006
- Review panel
- Unknown
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files