Medhot Mti 2000 Thermal Imaging System
System, Telethermographic (Adjunctive Use). 510(k) K063047, from Medhot Thermal Imaging, Inc. (Great Neck, NY). Product code LHQ, class 1.
As of Nov 21, 2026, K063047 is an FDA 510(k) held by Medhot Thermal Imaging, Inc., substantially equivalent on Oct 19, 2006 after 15 days, with 1 recall tied to it in FDA's recall database.
- Review time: 15 days
- Recalls: 1
- Cited as a predicate by: 2 devices
Intended for qualified healthcare personnel who are trained in its use, the MedHot MTI 2000 is a non-contact, non-invasive, non-radiating, thermographic imaging device for use as an adjunct to other clinical diagnostic procedures in the capture, quantification, and screening, of differences in skin surface temperature changes.
- Telethermographic Camera, Series A, E, S and PK033967 · Flir Systems · Mar 9, 2004
- InTouch Thermal CameraK181716 · Intouch Technologies, Inc., D.B.A. Intouch Health · Mar 25, 2019
- Med-Hot Thermal Imaging SystemsK171928 · Med-Hot Thermal Imaging, Inc. · Dec 8, 2017
| Started | Recall | Status |
|---|---|---|
| Jan 14, 2017 | Z-2057-2017Indications for use are not cleared or approved for market in the U.S. | Terminated |
- Derma-2K253911 · Neko Health AB · May 20, 2026
- ThermPix Thermovisual CameraK232462 · Usa Therm, Inc. · Sep 14, 2023
- ThermPix Thermovisual CameraK213650 · Usa Therm, Inc. · Apr 12, 2022
- Smile-100 SystemK212965 · Niramai Health Analytix Private Limited · Mar 10, 2022
- Iris-XpK212412 · Medicore Co., Ltd. · Sep 13, 2021
- Thermidas IR System (ThIR-A615)K200999 · Thermidas Americas, Inc. · Jan 6, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Oct 4, 2006
- Review panel
- Obstetrics/Gynecology
- Regulation
- 21 CFR 884.2980
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files