Test, Time, Prothrombin. 510(k) K062925, from Roche Diagnostics Corp. (Indianapolis, IN). Product code GJS, class 2.

As of Nov 19, 2026, K062925 is an FDA 510(k) held by Roche Diagnostics Corp., substantially equivalent on Jan 29, 2007 after 123 days, with 4 recalls tied to it in FDA's recall database.

  • Review time: 123 days
  • Recalls: 4
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The CoaguChek XS PT test strips are part of the CoaguChek XS System. The CoaguChek XS System measures blood-clotting time for people who are taking anticoagulation medications such as Coumadin® or warfarin. The CoaguChek XS System uses blood from a finger stick.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K062925, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Dec 2, 2020Z-0804-2021Possible Misinterpretation of Displayed Measuring Units from INR to %Quick or Seconds; providing instructions to users for ensuring the meter is displaying INR resultsTerminated
May 16, 2013Z-1581-2013Roche has confirmed the potential for an undetected elevated INR test result with the CoaguChek XS, CoaguChek XS Plus, and CoaguChek XS Pro meters. In rare cases, instead of a value, an ERROR 6 message is displayed.Terminated
Jul 22, 2009Z-2003-2009The recommended cleaning procedures for the meter may cause a malfunction and falsely elevated test result reports.Terminated
May 13, 2009Z-1594-2009The lancet cap may be missing, which could result in an unintended lancet stick to the user.Terminated

Other GJS clearances

The newest 510(k)s for the same product code; their median review was 299 days; see every GJS device

Record

Type
Traditional
Received
Sep 28, 2006
Review panel
Hematology
Regulation
21 CFR 864.7750

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files