GE Datex-Ohmeda Engstrom Carestation
Ventilator, Continuous, Facility Use. 510(k) K062710, from Datex-Ohmeda, Inc. (Madison, WI). Product code CBK, class 2.
As of Nov 19, 2026, K062710 is an FDA 510(k) held by Datex-Ohmeda, Inc., substantially equivalent on Dec 8, 2006 after 88 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 88 days
- Recalls: 2
- Cited as a predicate by: 3 devices
The GE Datex-Ohmeda Engström Carestation is designed to provide mechanical ventilation for adults and pediatrics weighing 5kg and above having degrees of pulmonary impairment varying from minor to severe. Optional Neonatal capabilities expand the patient range to 0.5 kg.
- GE Datex-Ohmeda Engstrom CarestationK051895 · Datex-Ohmeda, Inc. · Sep 27, 2005
- GE Datex-Ohmeda Engstrom CarestationK060862 · Datex-Ohmeda, Inc. · Jun 5, 2006
- Anatomical Shoulder Keeled GlenoidK051623 · Zimmer GmbH · Jul 19, 2005
- Engstrom Carestation, Engstrom ProK081842 · Datex-Ohmeda, Inc. · Oct 3, 2008
- Modification To Hamilton-G5K081521 · Hamilton Medical AG · Sep 25, 2008
- Modification To Galileo GoldK080181 · Hamilton Medical AG · Jun 24, 2008
| Apr 23, 2008 | Z-1829-2008There is a correction associated with Engstrom Carestation with an integrated Aerogen Professional Nebulizer System. There is an issue relating to the removal of the nebulizer cable from nebulizer connection port,… | Terminated |
| Jul 2, 2007 | Z-1526-2008Neonatal Flow Sensors supplied for use with the Neonatal Enhancement for the Engstrm Carestation may result in the sensors providing invalid values and alarm messages when exposed to high flow rates. | Terminated |
- Evita (V800); Evita (V600)K253647 · Draegerwerk AG & CO Kgaa · May 7, 2026
- Inbentus VersatileK252663 · Iconic Solutions by Murcia, SL · Apr 14, 2026
- VPAP Pediatric Face MaskK251888 · Hsiner Co., Ltd. · Mar 12, 2026
- Vivo 45 LSK232365 · Oconnell Regulatory Consultants, Inc. · Dec 19, 2025
- F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size A (ONIV117A); F&P OptiNIV…K252173 · Fisher & Paykel Healthcare, Ltd. · Sep 10, 2025
- SV600, SV800 VentilatorK243767 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Aug 28, 2025
- AVEA disposable expiratory filter/water trap (11790)K251133 · Telesair, Inc. · May 8, 2025
- AF531 Oro-Nasal SE Face MaskK243394 · Respironics, Inc. · Dec 30, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 11, 2006
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5895
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files