Philips SPO2 Reusable Sensor, Models M1196A and M1196T
Oximeter. 510(k) K062605, from Philips Medical Systems (Andover, MA). Product code DQA, class 2.
As of Nov 18, 2026, K062605 is an FDA 510(k) held by Philips Medical Systems, substantially equivalent on Nov 9, 2006 after 65 days, with no recalls tied to it in FDA's recall database.
- Review time: 65 days
- Recalls: 0
- Cited as a predicate by: 4 devices
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Models M1175A & M1176A Component Monitoring SystemK882609 · Waltham Div. Hewlett Packard · Jan 19, 1989
- HP Viridia Component Monitoring System, HP Viridia Cms 24/26, HP Viridia Multi-Measurement Server and Compact Portable TK990972 · Hewlett-Packard GmbH · Apr 19, 1999
- Agilentcomponent Monitoring System, Agilent 24/26, Agilent Multi-Measurement Server and Compact Portable Patient MonitorK000822 · Agilent Technologies, GmbH · Apr 6, 2000
- Picosat Ii SPO2 Pulse Oximetry ModuleK030973 · Philips Medical Systems · Jul 23, 2003
- Philips SPO2 Reusable Sensors, Model Nos. M1191T, M1192T, and M1193TK032979 · Philips Medical Systems, Inc. · Feb 20, 2004
Cited as a predicate
4 later 510(k) summaries name this device as a predicate- Reusable Adult SpO2 Clip Sensor (3m) (M1196A); Reusable Adult SpO2 Clip Sensor (0.9m) (M1196T)K252821 · Philips Medizin Systeme Böblingen GmbH · May 29, 2026
- Unimed Reusable Finger Clip SpO2 Sensors (UXXX-91 Series) (U403-91); Unimed Reusable Finger Clip SpO2 Sensors (UXXX-91…K243086 · Unimed Medical Supplies, Inc. · Feb 20, 2025
- Reusable Envitec Finger SPO2 Sensor-Hp/Philips Compatible, Models F-2412, F-2414-15, Reusable Envitec Ear SPO2 SensorK090438 · Envitec-Wismar GmbH · Jul 24, 2009
- Philips Reusable SPO2 Sensors M1191T, M1192T and M1193T, Clip Sensor M1196T and Disposable SPO2 Sensors M1131A, M1132AK063783 · Philips Medical Systems, Inc. · Apr 27, 2007
Other DQA clearances
The newest 510(k)s for the same product code; their median review was 207 days; see every DQA device- ANNE LimbK261870 · Sibel Health · Nov 5, 2026
- Ninenovo Blood Oxygen Ring…K260490 · Shenzhen Ninenovo Technology Limited · Oct 2, 2026
- Reusable Adult SpO2 Clip Sensor (3m) (M1196A); Reusable Adult SpO2 Clip Sensor (0.9m) (M1196T)K252821 · Philips Medizin Systeme Böblingen GmbH · May 29, 2026
- Pulse Oximeter (PO-A2AO, PO-A2AT, PO-A3AO, PO-H1AO, PO-B1AO, PO-C5AO, PO-C5AT, PO-C6AO, PO-C6AT)K252655 · Shenzhen Imdk Medical Technology Co., Ltd. · May 11, 2026
- Nasal Alar SpO2 Sensor (989803205381); Nasal Alar SpO2 Sensor (989803205391); Nasal Alar Sp02 Sensor (989803205401)K253887 · Philips Medizin Systeme · May 1, 2026
- Unimed Reusable Finger Clip SpO2 Sensors (U403-49R and U103-49R)K260931 · Unimed Medical Supplies, Inc. · Apr 14, 2026
- AViTA Pulse Oximeter (SP61)K252448 · Avita Corporation · Feb 27, 2026
- YUWELL® Finger Pulse Oximeter (YX105, YX106, YX110, YX310)K252805 · Jiangsu Yuyue Medical Equipment & Supply Co., Ltd. · Feb 17, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Sep 5, 2006
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2700
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files