Neuviz Dual Multi-Slice CT Scanner System
System, X-Ray, Tomography, Computed. 510(k) K062451, from Neusoft Medical Systems Co., Ltd. (Shenyang, Liaoning, CN). Product code JAK, class 2.
As of Nov 19, 2026, K062451 is an FDA 510(k) held by Neusoft Medical Systems Co., Ltd., substantially equivalent on Sep 28, 2006 after 37 days, with 6 recalls tied to it in FDA's recall database.
- Review time: 37 days
- Recalls: 6
- Cited as a predicate by: 1 device
The NeuViz Dual Multi-slice CT Scanner System -NeuViz Dual (H) and NeuViz Dual (L) - are intended to produce cross-section images of head and body by computer reconstruction of X-ray transmission data taken at different angles.
- CT-C3000DUAL and CT-C2800DUAL Family of Dual-Slice CT Scanner SystemsK041542 · Neusoft Digital Medical Systems Co., Ltd. · Jun 17, 2004
- Modification To Neuviz Dual Multi-Slice CT Scanner SystemK071308 · Neusoft Medical Systems Co., Ltd. · Aug 16, 2007
| Oct 18, 2012 | Z-0466-2013The four screws that secure the patient table top to the carrier pulled out and caused the table top to detach. This issue may affect NeuViz Dual and NeuViz 16 scanners. | Terminated |
| Feb 10, 2010 | Z-0846-2011Potential for the CT patient table top to become detached from the carrier due to missing washers. | Terminated |
| Jul 21, 2008 | Z-2237-2010The reference lines for image generated for a Surview scan may appear in the incorrect position in the "FILM" display mode. | Terminated |
| Jun 23, 2008 | Z-2307-2008Potential for R-host box and components inside to be detached of its mounting during the gantry rotor rotation. There is a potential for components to be damaged inside the system gantry and for the internal components… | Terminated |
| Apr 10, 2008 | Z-0001-2009An issue associated with the "Timed Scan" application was found. The system does not wait for the programmed time interval and starts the x-ray after selection of the scan button when certain criteria is met. | Terminated |
| Dec 17, 2007 | Z-2235-2008Labeling of patient position on scanned image does not match actual patient orientation. | Terminated |
- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Aug 22, 2006
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files