Arca
Skip to content
Tools
Tools

Eclipse Tcd Neurovascular Workstation and 2 more

Stimulator, Electrical, Evoked Response. 510(k) K061639, from Axon Systems, Inc. (Hauppauge, NY). Product code GWF, class 2.

As of Nov 18, 2026, K061639 is an FDA 510(k) held by Axon Systems, Inc., substantially equivalent on Nov 1, 2006 after 142 days, with no recalls tied to it in FDA's recall database.

  • Substantially equivalent: Nov 1, 2006
  • Review time: 142 days
  • Recalls: 0
  • Cited as a predicate by: 1 device

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The systems are intended for use to monitor sensory and motor pathways and to provide information to determine the state of blood flow in the intracranial and extracranial vascular arteries in adults. The instrument uses electroencephalography (EEG), electromyography (EMG), motor and sensory evoked potentials and nerve potentials and Doppler analysis.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

1 later 510(k) summary names this device as a predicate

Other GWF Clearances

The newest 510(k)s for the same product code; their median review was 94 days; see every GWF device

Record

Type
Traditional
Received
Jun 12, 2006
Review panel
Neurology
Regulation
21 CFR 882.1870

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.