Evolve Modular Radial Head

Prosthesis, Elbow, Hemi-, Radial, Polymer. 510(k) K060731, from Wrightmedicaltechnologyinc (Arlington, TN). Product code KWI, class 2.

As of Nov 19, 2026, K060731 is an FDA 510(k) held by Wrightmedicaltechnologyinc, substantially equivalent on Apr 19, 2006 after 30 days, with 5 recalls tied to it in FDA's recall database.

  • Review time: 30 days
  • Recalls: 5
  • Cited as a predicate by: 4 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Use of the Modular Radial Head Implant may be considered for : - Replacement of the radial head for degenerative or post-traumatic disabilities presenting pain, crepitation, and decreased motion at the radio-humeral and/or proximal radio-ulnar joint with: a. joint destruction and/or subluxation visible on x-ray; and/or b. resistance to conservative treatment.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

4 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K060731, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 3, 2022Z-0005-2023, Z-0006-2023The outer label does not match the device inside the package. The affected lot of EVOLVE Proline Stem 7.5mm +2 contains a size 9.5mm +4 stem, while the affected lot of EVOLVE Proline Stem 9.5mm +4 contains a size 7.5mm…Open
Aug 26, 2020Z-2989-2020Lack of sterility assuranceTerminated
Dec 27, 2019Z-1101-2020, Z-1102-2020Two lots of EVOLVE Modular Radial Head could have the wrong size product in the package. Both the label and laser marking are incorrect on the affected product.Terminated

Other KWI clearances

The newest 510(k)s for the same product code; their median review was 129 days; see every KWI device

Record

Type
Special
Received
Mar 20, 2006
Review panel
Orthopedic
Regulation
21 CFR 888.3170

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files