Dimension Tbi Flex and Dbi Flex Reagent Cartridges and Tbi/Dbi Calibrator

Diazo Colorimetry, Bilirubin. 510(k) K060628, from Dade Behring, Inc. (Newark, DE). Product code CIG, class 2.

As of Nov 18, 2026, K060628 is an FDA 510(k) held by Dade Behring, Inc., substantially equivalent on Apr 6, 2006 after 28 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 28 days
  • Recalls: 1
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

TBI Flex® reagent cartridge: The TBI method for the Dimension® clinical chemistry system is an in vitro diagnostic test intended to quantitatively measure total bilirubin in human serum and plasma. Measurements of total bilirubin are used in the diagnosis and treatment of liver, hemolytic, hematological, and metabolic disorders, including hepatitis and gallbladder disease.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K060628, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Feb 13, 2020Z-1540-2020Bilirubin assays may exhibit a positive bias with patients on eltrombopag therapyTerminated

Other CIG clearances

The newest 510(k)s for the same product code; their median review was 245 days; see every CIG device

Record

Type
Special
Received
Mar 9, 2006
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1110

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files