Source Production & Equipment Co, Inc., Model M-19 IR-192 Brachytherapy Source
System, Applicator, Radionuclide, Remote-Controlled. 510(k) K052947, from Source Production & Equipment Co., Inc. (Saint Rose, LA). Product code JAQ, class 2.
As of Nov 20, 2026, K052947 is an FDA 510(k) held by Source Production & Equipment Co., Inc., substantially equivalent on Apr 19, 2006 after 181 days, with 1 recall tied to it in FDA's recall database.
- Review time: 181 days
- Recalls: 1
- Cited as a predicate by: 1 device
Source Production & Equipment Co., Inc. (SPEC) Model M-19 Source Assembly, with individual activity up to 12 Ci, is indicated for temporary interstitial, intracavitary, intraluminal or intraoperative or surface application to treat selected localized tumors.
- Gammamed 212 and 232 Source AssemblyK030745 · Varian Medical Systems · Mar 12, 2003
- Microselectron-Hdr Version 2K953946 · Nucletron-Oldelft Corp. · Aug 13, 1996
- 10 Curie Irdium 192, CSN00100-192K991571 · Alpha-Omega Services, Inc. · Feb 22, 2000
- ACU007SK092522 · Oncology Systems, Inc. · Nov 20, 2009
| Started | Recall | Status |
|---|---|---|
| Mar 3, 2008 | Z-1717-2009Radioactive source broke during use. | Terminated |
- LumenCare AzureK262383 · Nucletron B.V. · Jul 24, 2026
- MAASTRO Rectal Applicator SetK252717 · Varian Medical Systems · May 20, 2026
- Rectal ApplicatorK251037 · Nucletron B.V. · Dec 19, 2025
- Guided Aarhus Applicator SetK252884 · Varian Medical Systems · Nov 19, 2025
- CT/ MR Tandem and Ovoid SetK250299 · Varian Medical Systems, Inc. · May 9, 2025
- Intracavitary/Interstitial SystemK250289 · Varian Medical Systems · Apr 25, 2025
- Titanium Flexible Geometry FSD Applicator Set (GM11013400)K243939 · Varian Medical Systems, Inc. · Mar 3, 2025
- Mould Probe MR SafeK241764 · Varian Medical Systems, Inc. · Jan 10, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Oct 20, 2005
- Review panel
- Radiology
- Regulation
- 21 CFR 892.5700
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files