Tandemheart Transseptal Cannula Set-Ef, Model 5140-6221

Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass. 510(k) K052570, from Cardiacassist, Inc. (Pittsburgh, PA). Product code DWF, class 2.

As of Nov 22, 2026, K052570 is an FDA 510(k) held by Cardiacassist, Inc., substantially equivalent on Jan 17, 2006 after 120 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 120 days
  • Recalls: 1
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The TandemHeart Transseptal Cannula Set – EF is intended for transseptal catheterization of the left atrium via the femoral vein for the purpose of providing a means for temporary (six hours or less) left ventricular bypass when connected to the TandemHeart extracorporeal blood pump which returns blood to the patient via the femoral artery or other appropriate site. AND/OR

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K052570, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Dec 2, 2010Z-0889-2011Component (Dilator of TandemHeart Transseptal Cannula Set-EF) does not meet specificationsTerminated

Other DWF clearances

The newest 510(k)s for the same product code; their median review was 91 days; see every DWF device

Record

Type
Traditional
Received
Sep 19, 2005
Review panel
Cardiovascular
Regulation
21 CFR 870.4210

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files