Catheter, Percutaneous. 510(k) K052257, from Vascular Solutions, Inc. (Minneapolis, MN). Product code DQY, class 2.

As of Nov 19, 2026, K052257 is an FDA 510(k) held by Vascular Solutions, Inc., substantially equivalent on Nov 23, 2005 after 97 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 97 days
  • Recalls: 1
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Twin-Pass Dual Access Catheter is to be used in conjunction with steerable guidewires in order to access discrete regions of the coronary and peripheral arterial vasculature, to facilitate placement of guidewires and other interventional devices, and for use during two guidewire procedures.

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K052257, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Sep 16, 2016Z-0053-2017Vascular Solutions is recalling Twin-Pass dual access catheters because there is a potential for excess manufacturing material to remain at the tip of the catheter or within the distal portion of the rapid exchange…Terminated

Other DQY clearances

The newest 510(k)s for the same product code; their median review was 42 days; see every DQY device

Record

Type
Traditional
Received
Aug 18, 2005
Review panel
Cardiovascular
Regulation
21 CFR 870.1250

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files