Ultraclean Handcontrolled Suction Coagulator, Model 130182, 130183, 130184, 130185 and 1 more
Electrosurgical, Cutting & Coagulation & Accessories. 510(k) K052104, from Conmed Corporation (Centennial, CO). Product code GEI, class 2.
As of Nov 20, 2026, K052104 is an FDA 510(k) held by Conmed Corporation, substantially equivalent on Oct 21, 2005 after 79 days, with 1 recall tied to it in FDA's recall database.
- Review time: 79 days
- Recalls: 1
- Cited as a predicate by: 1 device
Single-use electrosurgical accessory used to provide coagulation therapeutic energy to tissue and suction to aspirate blood, coagulum and small bits of tissue debris from the surgical site. The coagulation effect is achieved by the passage of high frequency current through the tissue of interest.
- Suction CoagulatorK033003 · Modern Medical Equipment Mfg., Ltd. · May 13, 2004
- Fas-Clean Electrosurgical Coated Active BladeK073616 · Electromedics Co. , Ltd. · Jul 23, 2008
| Started | Recall | Status |
|---|---|---|
| Sep 30, 2009 | Z-0165-2010One production lot of Suction Coagulators received ETO sterilization instead of gamma radiation sterilization. | Terminated |
- SP Electrocautery Device (SP18 Max);SP Electrocautery Device (SP20 Max)K262720 · Single Pass, Inc. · Oct 26, 2026
- SafeAir Electrosurgical Generator with Smoke Evacuation (0795-001-000);SafeAir Generator 3-Pedal Footswitch…K262386 · Stryker Instruments · Oct 20, 2026
- HARMONIC 1100 Shears (HAR1120); HARMONIC 1100 Shears (HAR1136)K254196 · Ethicon Endo-Surgery, LLC · Sep 17, 2026
- Neptune® SafeAir® 10ft Smoke Evacuation Pencil, Square Coated, 70mm Blade, Push Button Switch (0703-046-100);Neptune®…K261959 · Stryker Instruments · Sep 17, 2026
- LigaSure™ RAS Maryland Jaw Vessel Sealer/Divider, Nano-coatedK261070 · Covidien, LLC · Sep 15, 2026
- Potenza PrimeK254185 · Jeisys Medical Incorporated · Sep 11, 2026
- Ellian Enigma RF DeviceK262364 · Ellian Corp · Sep 2, 2026
- Scarlet Pro (Scarlet Pro)K253859 · VIOL Co., Ltd. · Aug 27, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 3, 2005
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4400
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files