Revolution Xr/D Digital Radiographic Imaging System With Tomosynthesis
System, X-Ray, Stationary. 510(k) K051967, from GE Healthcare (Waukesha, WI). Product code KPR, class 2.
As of Nov 20, 2026, K051967 is an FDA 510(k) held by GE Healthcare, substantially equivalent on Aug 9, 2005 after 20 days, with 9 recalls tied to it in FDA's recall database.
- Review time: 20 days
- Recalls: 9
- Cited as a predicate by: 2 devices
Revolution XR/d Digital Radiographic Imaging System is indicated for use in generating Tomographic images of human anatomy. This device is not intended for mammographic applications.
- Tomo-LinkK944967 · GE Medical Systems · Dec 9, 1994
- Revolution Xr/D Digital Radiographic Imaging SystemK012389 · Ge Medical Systems, Inc. · Aug 10, 2001
- Discovery XR656 With Volumerad (Digital Tomosynthesis)K132261 · Ge Medical Systems, LLC · Nov 18, 2013
- Fujifilm Tomosynthesis Option for Fdr Acselerate Stationary X-Ray SystemK121499 · Fujifilm Medical System U.S.A., Inc. · Nov 20, 2012
| Oct 26, 2011 | Z-1065-2012GE Healthcare has become aware of a potential issue associated with the hand grip that is clamped to the table top of your Revolution XRD X-ray systems that may impact patient safety. The hand grip accessory that is… | Terminated |
| Aug 13, 2009 | Z-0528-2010Certain GE Radiographic fixed X-ray tables (Proteus XR/a, Revolution XR/d, and Definium 8000) were found to have tabletops that move unexpectedly in a bi-directional mode. In rare cases, a malfunction may occur, which… | Terminated |
| Mar 7, 2008 | Z-1822-2008Loss of image data: Software anomaly in the Processing Software on the Definium 8000 system may impact patient safety when using the VolumeRAD advanced application (option). The slice visualization of VolumeRAD exams… | Terminated |
| Mar 7, 2008 | Z-1882-2008Radiation dose reading greater than actual dose: Error in the generator software on the GE Healthcare Revolution XR/d configured with HP 8200 PC consoles and all Definium 8000 systems may impact patient safety.… | Terminated |
| Feb 14, 2008 | Z-0002-2009GE Healthcare has recently become aware of a potential risk of observing a blank image after exposure on Revolution XR/d systems equipped with HP 8200 PC user consoles that may impact patient safety. It was reported… | Terminated |
| Feb 14, 2008 | Z-0003-2009GE Healthcare has recently become aware of an error in the generator software on the Revolution XR/d configured with HP 8200 PC consoles that reports a mAs reading that is higher than is actually exposed to patients. | Terminated |
| Jan 2, 2008 | Z-1883-2008Not properly labeling the manual switch for disabling positive beam limitation (PBL) located on the overhead tube support user interface as required | Terminated |
| Aug 13, 2007 | Z-1476-2008Necessary certification labels are missing from the x-ray contol. | Terminated |
| May 31, 2006 | Z-1788-2012An incident was reported that an operator's finger was pinched between the fixed roller and the gliding tabletop of a Proteus XR/a Table while moving the tabletop with the thumb placed over its edge and fingers… | Terminated |
- EXSYS DEXi (EXSYS DEXi-S40S); EXSYS DEXi (EXSYS DEXi-S40P); EXSYS DEXi (EXSYS DEXi-S40T); EXSYS DEXi (EXSYS DEXi-S50HK260227 · DRTECH Corporation · Sep 8, 2026
- MULTIX Impact; MULTIX Impact CK260488 · Siemens Medical Solutions USA, Inc. · Aug 31, 2026
- GC85AK260481 · Samsung Electronics Co., Ltd. · Aug 27, 2026
- DRE DuoK260482 · Jpi Healthcare Co, Ltd. · Jun 15, 2026
- AeroDR TX c02K253446 · Dk Medical Systems Co., Ltd. · Apr 10, 2026
- DRX-Evolution Plus X-ray System, DRX-Compass Mobile X-ray System, Lux HD 35 detector, Lux HD 43 detectorK250954 · Carestream Health · Jan 20, 2026
- uDR Arria & uDR ArisK252000 · Shanghai United Imaging Healthcare Co., Ltd. · Nov 26, 2025
- uDR Aurora CXK251167 · Shanghai United Imaging Healthcare Co., Ltd. · Sep 19, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 20, 2005
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1680
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files