Patient Monitor, Models Dash 3000, 4000 and 5000
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms). 510(k) K051367, from Ge Medical Systems Information Technologies (Tampa, FL). Product code MHX, class 2.
As of Nov 19, 2026, K051367 is an FDA 510(k) held by Ge Medical Systems Information Technologies, substantially equivalent on Jun 20, 2005 after 26 days, with 1 recall tied to it in FDA's recall database.
- Review time: 26 days
- Recalls: 1
- Cited as a predicate by: 1 device
The DASH 3000/4000/5000 Patient Monitor is intended for use under the direct supervision of a licensed healthcare practitioner. The intended use of the system is to monitor physiologic parameter data on adult, pediatric and neonatal patients.
- Modification To Dash 3000/4000 Patient MonitorK033304 · Ge Medical Systems Information Technologies · Nov 12, 2003
- Oximax Pulse Oximetry System With N-595 Pulse Oximeter and Oximax Sensors and Cables (Aka Accessories)K012891 · Nellcor Puritan Bennett, Inc. · Mar 7, 2002
- Datex-Ohmeda 3800+/3800P+ Or 3900/3900P Pulse OximetersK983684 · Datex-Ohmeda, Inc. · Nov 6, 1998
- BisxK040183 · Aspect Medical Systems, Inc. · Feb 25, 2004
- Modification To Dash 3000, 4000, 5000 Monitor and AccessoriesK073462 · Ge Medical Systems Information Technologies · Jan 11, 2008
| Started | Recall | Status |
|---|---|---|
| Aug 31, 2018 | Z-0521-2019The patient monitors may simultaneously restart as designed if all are connected to the same network and a network overload occurs for a prolonged time. | Open |
- 12SL PrecisionK261307 · Ge Medical Systems Information Technologies, Inc. · Nov 3, 2026
- Radius VSM and AccessoriesK260676 · Masimo Corporation · Oct 14, 2026
- Carescape ONE; Carescape Dock F0; TruSignal ECG MM; TruSignal PRES MM; TruSignal TEMP MM; TruSignal SpO2 MM 1.8M;…K260656 · GE Healthcare Finland Oy · Sep 1, 2026
- Carescape Canvas 1000; Carescape Canvas Smart DisplayK260343 · GE Healthcare Finland Oy · Aug 28, 2026
- Infinity® Acute Care System (IACS) – VG8.1K260579 · Draeger Medical Systems, Inc. · Aug 20, 2026
- Telemetry Monitor (iT30, iT50)K251508 · Edan Instruments, Inc. · Aug 6, 2026
- Monitor B105M; Monitor B125M; Monitor B155M; Monitor B105P; Monitor B125PK253277 · Ge Medical Systems Information Technologies, Inc. · Jul 24, 2026
- Radius VSM and AccessoriesK254209 · Masimo Corporation · Jun 4, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- May 25, 2005
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1025
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files