Solid State X-Ray Imager (Flat Panel/Digital Imager). 510(k) K050925, from Shimadzu Corp. (Torrance, CA). Product code MQB, class 2.
As of Nov 21, 2026, K050925 is an FDA 510(k) held by Shimadzu Corp., substantially equivalent on Jun 1, 2005 after 49 days, with no recalls tied to it in FDA's recall database.
- Review time: 49 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The digital radiography unit DAR-7000 is a radiography system for a general acquisition using the flat panel sensor as X-ray detector. X-ray detector equipped with FPD (Flat Panel Detector) allows user to acquire a high-quality image. This system is designed to display digitizing the image, and to register or manipulate that image data. This unit is not used for mammography.
- Drf 4343K080859 · Villa Sistemi Medicali S.P.A. · Jun 4, 2008
- Intuition, Model 0170K073632 · Arcoma AB · Jan 10, 2008
- DAR-8000FK052500 · Shimadzu Medical Systems · Oct 17, 2005
- 0909FCE, 0909FCE-HSK253800 · Rayence Co., Ltd. · Jul 31, 2026
- Vivix-S 4386W (FXRD-4386WA)K260820 · Vieworks Co., Ltd. · Jun 18, 2026
- Universal 1417PIK252996 · Konica Minolta Healthcare Americas, Inc. · Jun 12, 2026
- Lux HD 2530 detector (Lux HD 2530)K252911 · Iray Imaging Technology (Haining) Limited · Oct 9, 2025
- Yushan X-Ray Flat Panel DetectorK250211 · Innocare Optoelectronics Corp. · Jul 22, 2025
- Skr 3000K250665 · Konica Minolta, Inc. · Jun 17, 2025
- Wireless/ Wired X-Ray Flat Panel DetectorsK243734 · Allengers Medical Systems Limited · Apr 18, 2025
- Expd 114; Expd 114G; Expd 114P; Expd 114PGK242770 · DRTECH Corporation · Mar 20, 2025
- Type
- Abbreviated
- Received
- Apr 13, 2005
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1680
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files