Cosman RF Lesion Generator, Model RFG-1A and 2 more

Probe, Radiofrequency Lesion. 510(k) K050084, from Cosman Medical, Inc. (Burlington, MA). Product code GXI, class 2.

As of Nov 19, 2026, K050084 is an FDA 510(k) held by Cosman Medical, Inc., substantially equivalent on Mar 17, 2005 after 63 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 63 days
  • Recalls: 3
  • Cited as a predicate by: 6 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

"The Cosman Radiofrequency Lesion Generator, Model RFG-1A, and associated Radiofrequency Lesion Probes, is indicated for use in procedures to create radiofrequency lesions for the treatment of pain, or for lesioning nerve tissue for functional neurosurgical procedures."

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

6 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K050084, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 29, 2026Z-2403-2026, Z-2402-2026Reusable electrodes may not meet expected performance levels.Open
Jul 5, 2017Z-0687-2018After multiple reprocessing cycles, the epoxy resin which holds the TCN Electrode in the hub can exhibit signs of damage. In some cases, this damage may result in the inability to fully remove blood and/or tissue…Terminated

Other GXI clearances

The newest 510(k)s for the same product code; their median review was 132 days; see every GXI device

Record

Type
Traditional
Received
Jan 13, 2005
Review panel
Neurology
Regulation
21 CFR 882.4725

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files