4.5MM Bone-Lok Facet Screw, Models TFCD-45-3040S Or N and 1 more
System, Facet Screw Spinal Device. 510(k) K043351, from Triage Medical, Inc. (Irvine, CA). Product code MRW, class U.
As of Nov 20, 2026, K043351 is an FDA 510(k) held by Triage Medical, Inc., substantially equivalent on Feb 18, 2005 after 74 days, with 1 recall tied to it in FDA's recall database.
- Review time: 74 days
- Recalls: 1
- Cited as a predicate by: 1 device
The 4.5mm BONE-LOK ® Facet Screw is indicated for spondylolisthesis, spondylolysis, degenerative disc disease (DDD) as defined by back pain of discogenic origin as confirmed by radiographic studies, degeneration of the facets with instability and fracture, pseudoarthrosis or failed previous fusion.
- NuVasive Triad Facet Screw SystemK020411 · Nuvasive, Inc. · Mar 12, 2002
- Single Use Perpos Pls System, 4.5 Bone-Lok Pls ImplantK082795 · Interventional Spine, Inc. · Dec 12, 2008
| Started | Recall | Status |
|---|---|---|
| Mar 15, 2011 | Z-3034-2011This recall has been initiated due to Pull Pins that may disengage from the Facet Screw during the compression step, requiring that compression be completed with a device driver rather than the compression tool. Use of… | Terminated |
- Arthrex Spine Compression FT ScrewK262618 · Arthrex, Inc. · Sep 24, 2026
- Ion-LK261209 · SurGenTec, LLC · Jun 11, 2026
- CORUS™ Posterior Cervical Stabilization System 3D (CORUS™ PCSS 3D)K253676 · Providence Medical Technology, Inc. · May 14, 2026
- DiversiVy™ Facet Screw SystemK253432 · Vy Spine, LLC · Mar 19, 2026
- Ion-CK251714 · SurGenTec, LLC · Jan 16, 2026
- FFX Facet Fixation SystemK250679 · Sc Medica · Dec 4, 2025
- CORUS-LX ImplantK253190 · Providence Medical Technology, Inc. · Nov 20, 2025
- FFX Facet Fixation SystemK252153 · Sc Medica · Oct 16, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 6, 2004
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files