Fabius Gs/Fabius Tiro Anesthesia System
Gas-Machine, Anesthesia. 510(k) K042419, from Draeger Medical, Inc. (Telford, PA). Product code BSZ, class 2.
As of Nov 20, 2026, K042419 is an FDA 510(k) held by Draeger Medical, Inc., substantially equivalent on Oct 8, 2004 after 31 days, with 11 recalls tied to it in FDA's recall database.
- Review time: 31 days
- Recalls: 11
- Cited as a predicate by: 1 device
The Fabius GS/Fabius Tiro is indicated as a continuous flow anesthesia system. The Fabius GS/Fabius Tiro can be used for spontaneous, manually assisted, automatic, pressure support, or synchronized mandatory intermittent ventilation, delivery of gases and anesthetic vapor, and monitoring oxygen concentration, breathing pressure and respiratory volume of patients during anesthesia.
- Fabius GS Anesthesia System; Fabius Tiro Anesthesia SystemK042086 · Draeger Medical, Inc. · Aug 31, 2004
- Evita 4K961687 · Drager, Inc. · Dec 13, 1996
- Datex-Ohmeda 7900 Ventilator EnhancementsK023366 · Datex-Ohmeda, Inc. · Oct 7, 2003
- Fabius MriK072884 · Draeger Medical AG & Co. KG · Jul 30, 2008
| May 24, 2018 | Z-2250-2018, Z-2251-2018The Draeger anesthesia device may be able to dose 100% N2O. In the event of a fault, the S-ORC module would not prevent setting an N2O flow that would result in a hypoxic mixture from being dosed to the patient.… | Terminated |
| Mar 1, 2018 | Z-1482-2018, Z-1484-2018, Z-1483-2018The automatic ventilation may fail if the position detection of the motor is disturbed. If the ventilator cover is damaged, manual ventilation may also fail. | Terminated |
| Aug 14, 2013 | Z-0008-2014During final testing of the Draeger Fabius GS Premium, Fabius OS, and Fabius Tiro anesthesia machines, some units did not pass the high voltage test and the minimum clearance between an electrical component and the unit… | Terminated |
| Aug 26, 2010 | Z-2479-2010, Z-2478-2010potential failures to Electri-Cord Manufacturing AC power cord | Terminated |
| Jul 7, 2008 | Z-2338-2008The parent company became aware of instances where the lower side rail of the frame of the machine broke inwards when being moved across a threshold; resulting in the machine being unstable. | Terminated |
| Feb 5, 2008 | Z-1315-2008Detachment of Component: The chassis on some machines were manufactured out of specifications. As a result, the caster may break loose from the chassis. | Terminated |
| Oct 3, 2006 | Z-0048-2007One of four casters may break loose from chassis | Terminated |
- A5 Anesthesia System (A5); A7 Anesthesia System (A7)K253330 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Jun 25, 2026
- Atlan (A100); Atlan (A100 XL); Atlan(A350); Atlan (A350 XL)K252746 · Drägerwerk AG Co. Kgaa · May 21, 2026
- Codonics Safe Labeling System-Point of Care Station (PCS) (SLS-700i and related 610i, 620i, 630i series enabled to…K251352 · Codonics.Incorporated · Jul 11, 2025
- AtlanK230931 · Drägerwerk AG Co. Kgaa · Jul 23, 2023
- Carestation 750/750cK213867 · Datex-Ohmeda, Inc. · Mar 28, 2023
- A8, A9 Anesthesia SystemK201957 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Mar 26, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 7, 2004
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5160
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files