Iv Administration Sets With Ultrablock Uv-Resistant Tubing
Set, Administration, Intravascular. 510(k) K041490, from B.Braun Medical, Inc. (Allentown, PA). Product code FPA, class 2.
As of Nov 20, 2026, K041490 is an FDA 510(k) held by B.Braun Medical, Inc., substantially equivalent on Oct 29, 2004 after 147 days, with 1 recall tied to it in FDA's recall database.
- Review time: 147 days
- Recalls: 1
- Cited as a predicate by: 1 device
The IV Administration Sets with Ultrablock UV-Resistant Tubing are intended for the pump or gravity administration of IV fluids involving light sensitive solutions.
- Extension Set Light-Safe, Model BC565K021480 · Codan US Corp. · Jun 27, 2002
- Ap 34 Multi-Therapy Infusion PumpK082182 · Q-Core, Ltd. · Aug 15, 2008
| Started | Recall | Status |
|---|---|---|
| Nov 24, 2009 | Z-0677-2010System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and… | Terminated |
- Gravity Blood Sets with 200µm FilterK260261 · B.Braun Medical, Inc. · Oct 22, 2026
- Ecomed Disposable Administration SetsK254123 · Ecomed Solutions, LLC · Sep 11, 2026
- iiSure Infusion SetK261530 · Deka Research and Development · Jun 3, 2026
- AMSafe Administration Set (BA-70075, BA-70071-D, BA-70070, BA-70071-P, BA-70072, BA-70072-F, BA-70071-DF,…K252543 · Amsino International, Inc. · May 4, 2026
- PuraCath Firefly Needleless Connector IT (9005)K251375 · Puracath Medical, Inc. · Feb 12, 2026
- nSet+ Stabilization Set [6426733]; nSet+ Stabilization Set with nSyte Needle Free Connector (NFC) [6426731]; nSyte…K251257 · Np Medical · Dec 4, 2025
- BD Alaris Pump Infusion SetK250325 · Carefusion (Bd) · Oct 30, 2025
- EZ™ IV Administration SetK251814 · Epic Medical Pte. , Ltd. · Aug 29, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 4, 2004
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5440
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files