Catheter, Angioplasty, Peripheral, Transluminal. 510(k) K040954, from Abbott Laboratories, Inc. (Redwood City, CA). Product code LIT, class 2.
As of Nov 20, 2026, K040954 is an FDA 510(k) held by Abbott Laboratories, Inc., substantially equivalent on May 11, 2004 after 28 days, with no recalls tied to it in FDA's recall database.
- Review time: 28 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The Fox Plus PTA Catheter is intended for dilatation of lesions in the femoral, renal, iliac, popliteal, peroneal, and profunda arteries and native or synthetic arteriovenous dialysis fistulae. This catheter is not intended for the expansion or delivery of stents.
- Modification To Fox Pta CatheterK020854 · Jomed AG · Apr 11, 2002
- Modification To: Fox Plus Pta CatheterK080264 · Abbott Vascular-Vascular Solutions · Mar 26, 2008
- Fox SV Pta Catheter (82XXX Series). Fox Plus Pta Catheter (12XXX Series)K051519 · Abbott Laboratories (Perclose, Inc.) · Jun 21, 2005
- Parafleet NC 014 PTA Balloon Dilatation Catheter;Parafleet NC 018 PTA Balloon Dilatation CatheterK262590 · Brosmed Medical Co., Ltd. · Nov 2, 2026
- ZYLOX Hippo PTA Balloon Dilatation CatheterK260416 · Zylox Medtech Co., Ltd. · Sep 21, 2026
- NC PTA Balloon Dilatation CatheterK254212 · Kossel Medtech (Suzhou) Co., Ltd. · Sep 16, 2026
- WAVE PTA Balloon CatheterK260304 · WAVE Medical AG · May 20, 2026
- Armada™ 14 NC PTA CatheterK252512 · Abbott Medical · Feb 13, 2026
- Amethyst HP PTA OTW 0.035 CatheterK251915 · Natec Medical , Ltd. · Dec 18, 2025
- Passeo-35 Xeo Peripheral Dilatation Catheter; Passeo-18 Peripheral Dilatation Catheters; Passeo-14 Peripheral…K250706 · Biotronik, Inc. · Apr 4, 2025
- Parafleet SC 014 PTA Balloon Dilatation Catheter; Parafleet SC 018 PTA Balloon Dilatation Catheter; Parafleet SC 035…K243704 · Brosmed Medical Co., Ltd. · Feb 27, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Apr 13, 2004
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1250
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files