Cadence, Models 2001 and 2002
System, Monitoring, Perinatal. 510(k) K040903, from Edan Instruments, Inc. (Yonkers, NY). Product code HGM, class 2.
As of Nov 18, 2026, K040903 is an FDA 510(k) held by Edan Instruments, Inc., substantially equivalent on Sep 2, 2004 after 148 days, with no recalls tied to it in FDA's recall database.
- Review time: 148 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe Cadence Fetal Monitor, model 2001 for singletons and model 2002 for twins, is a fetal monitor for monitoring fetal well being during the antepartum period. It performs what is commonly called the non stress test. The Cadence Fetal Monitor 2001/2002 is to be used by trained medical personnel in hospitals clinics, physicians offices, and in the patients home by prescription or doctors orders.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Sonicaid FM820, Sonicaid FM830K002150 · Oxford Instruments · Mar 9, 2001
- Corometrics Model 171 and 172 Fetal MonitorK991905 · General Electric Medical Systems Information Techn · Sep 1, 1999
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- Cadence, Cadence Dual, Cadence Ii Fetal MonitorK082369 · Edan Instruments, Inc. · Nov 7, 2008
- Cadence IiK073221 · Edan Instruments, Inc. · Dec 28, 2007
Other HGM clearances
The newest 510(k)s for the same product code; their median review was 258 days; see every HGM device- Novii+ Wireless Patch SystemK254036 · Datex Ohmeda, Inc. · Aug 10, 2026
- ANNE MaternalK253021 · Sibel Health, Inc. · Feb 26, 2026
- Sonicaid Team3K250777 · Huntleigh Healthcare , Ltd. · Sep 19, 2025
- Fetal & Maternal Monitor (F15A, F15A Air)K241882 · Edan Instruments, Inc. · Aug 27, 2025
- Sonicaid Team3K241368 · Huntleigh Healthcare , Ltd. · Feb 3, 2025
- PeriCALM Patterns 3.0K241009 · Perigen, Inc. · Jan 10, 2025
- Avalon CL Fetal & Maternal (F&M) Pod (866488), Avalon CL Fetal & Maternal (F&M) Patch (989803196341)K233440 · Philips Medizin Systeme Boeblingen GmbH · Jul 2, 2024
- Novii+ Wireless Patch SystemK231964 · Datex Ohmeda · Dec 8, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 7, 2004
- Review panel
- Obstetrics/Gynecology
- Regulation
- 21 CFR 884.2740
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files